GET DEVICE INFORMATION (QUERY)
Query the firmware version of the connected M4315-PRO / M4320-PRO.
SEND
<command><sendinfo/></command>
RECEIVE
<info time=”
time
”>
Response time stamp, provided in UNIX time
<fwver>
FW
</fwver>
M4315/20-PRO firmware version
</info>
GET DEVICE SETTINGS (QUERY)
Query the outlet, button and trigger settings from the connected M4315-PRO / M4320-PRO.
SEND
<command><sendsettings/></command>
RECEIVE
<settings time=’
time
’>
Response time stamp, provided in UNIX time
<profile >
PROFILE
</profile>
Active outlet / trigger / delay profile
1 = Profile 1 (factory default)
2 = Profile 2
3 = Profile 3
4 = Profile 4
<dlys>
<dly id=”
outlet
”’ sf=”
off
”’ so=”
on
”/>
<cy id=”
outlet
”>
CYCLE
</cy>
</dlys>
Outlet bank delay settings
outlet
= outlet number
on
= sequence OFF delay
off
= sequence ON delay
CYCLE
= power cycle delay
<grps>
<dcin>
OUTLETS
</dcin>
<butt id=”
button
”>
OUTLETS
</butt>
</grps>
DC Trigger & Button Input Groups
OUTLETS
= affected outlets bitmap, expressed as a hexadecimal
value. LSB (bit 0) represents outlet 1, bit 7 represents outlet 8
button
= 1: Power cycle outlet with button 1
button
= 2: Power cycle outlet with button 2
button
= 3: Force outlet on/off with Button 1 AND Button 2