12
SEQUENCE OUTLETS (COMMAND)
SEND
<command><sequence/></command>
Initiates a timed outlet switching operation opposite of the previous
timed switching operation. Outlets will switch on (or off) after the set-
turn on and turn-off delays.
RECEIVE
None
No response
CHANGE SETTINGS (COMMAND)
SEND
<command><set>
MESSAGE
>/set></command>
RECEIVE
None
Setting
Description
Parameters
<profile>
n
</profile>
Set settings profile. Refer to
M4315/20-PRO manual for settings
for each profile.
n
= profile (1,2,3,4)
<dlys>
<dly id=’
outlet
’ sf=’
off
’ so=’
on
’/>
<cy butt=’
button
’>
delay
</cy>
</dlys>
Set outlet delay settings
outlet
= outlet number
off
= sequence OFF delay
on
= sequence ON delay
button
= button number {1,2,3}
delay
= power cycle delay for the selected
button
<grps>
<dcin>
OUTLETS
</dcin>
<butt id=’
button’>OUTLETS
</butt>
</grps>
Set input Groups
DC Trigger & Button Input Groups
OUTLETS
= affected outlets bitmap, expressed
as a hexadecimal value. LSB (bit 0) represents
outlet 1, bit 7 represents outlet 8
button
= 1: Power cycle outlet with button 1
button
= 2: Power cycle outlet with button 2
button
= 3: Force outlet on/off with Button 1
AND Button 2
Examples:
To set the configuration to preset profile 2
:
<command><set><profile>2</profile></set></command>
To set outlet 1 turn on delay to 5 seconds and turn off delay to 10 seconds:
<command><set><dlys><dly id=”1” sf=”10” so=”5”/></dlys></set></command>
To set the power cycle delay for Button 2 to 40 seconds:
<command><set><dlys><cy butt=”2”>40</cy></dlys></set></command>
To set outlets 1-4 to be affected by the DC trigger input (bitmap 0000 1111 = 0f):
<command><set><grps><dcin>0f</dcin></grps></set></command>
To set Button 2 to cycle outlets 5-8 (bitmap 1111 0000 = f0):
<command><set><grps><butt id=”2”>f0</butt></grps></set></command>