C3-IP Quick Start Guide
ADVANCED OPERATIONS
C3-IP Advanced Operation
The C3-IP has an embedded web page for users that wish to use the C3-IP on a LAN . The embedded webpage displays the units’ serial number, ethernet address (MAC ID),
firmware version, bootcode version, brand and model number . To find the C3-IP IP address, you can claim the device in BlueBOLT one time and look under Device ADMIN for
the IP address or you can use your networking devices . In some cases, your ISP modem may be equipped with a tool to locate the IP address of the C3-IP .
Status
The
Status
screen shows you the integrity of the power:
Voltage
,
Amperage
,
Wattage
,
Power Factor
and
Power VA
. The
Conditions
screen displays the
Power Condition
(detailed below), whether the
Breaker
is "opened" or "closed" and if the
Voltage Monitoring
is working .
Power Condition States
Normal
= Input voltage is within range
Undervoltage
= The voltage is so low that the over/under voltage load disconnect has engaged and all outlets are off .
Overvoltage
= The voltage is so high that the over/under voltage load disconnect has engaged and all outlets are off .
Recovery
= Recovery
1.
Recovering from an over/under voltage load disconnect condition
2.
Recovering after the breaker has been tripped and reset
3.
Recovering after the switch has been turned off and turned on again or a power cycle
4.
Recovery will also be stated when the unit is plugged into a live AC source .
Voltage Monitor States
Voltage Monitor
= okay – voltage is within a safe range
Voltage Monitor
= fault
1.
Either the over/under voltage load disconnect has engaged and all outlets are off .
2.
The breaker was tripped turning all outlets off
3.
The power switch was turned off, turning all outlets off .