C3-IP Quick Start Guide

ADVANCED OPERATIONS

C3-IP Advanced Operation

The C3-IP has an embedded web page for users that wish to use the C3-IP on a LAN . The embedded webpage displays the units’ serial number, ethernet address (MAC ID), 
firmware version, bootcode version, brand and model number . To find the C3-IP IP address, you can claim the device in BlueBOLT one time and look under Device ADMIN for 
the IP address or you can use your networking devices . In some cases, your ISP modem may be equipped with a tool to locate the IP address of the C3-IP .

Status

The 

Status

 screen shows you the integrity of the power: 

Voltage

Amperage

Wattage

Power Factor

 and 

Power VA

 . The 

Conditions

 screen displays the 

Power Condition

 

(detailed below), whether the 

Breaker

 is "opened" or "closed" and if the 

Voltage Monitoring

 is working .

Power Condition States

 

Normal

 = Input voltage is within range

 

Undervoltage

 = The voltage is so low that the over/under voltage load disconnect has engaged and all outlets are off . 

 

Overvoltage

 = The voltage is so high that the over/under voltage load disconnect has engaged and all outlets are off .

 

Recovery

 =  Recovery 

1. 

Recovering from an over/under voltage load disconnect condition

2. 

Recovering after the breaker has been tripped and reset

3. 

Recovering after the switch has been turned off and turned on again or a power cycle

4. 

Recovery will also be stated when the unit is plugged into a live AC source .

Voltage Monitor States

  Voltage Monitor

 = okay – voltage is within a safe range

  Voltage Monitor

 =  fault

1. 

Either the over/under voltage load disconnect has engaged and all outlets are off . 

2. 

The breaker was tripped turning all outlets off 

3. 

The power switch was turned off, turning all outlets off . 

Содержание BlueBOLT C3-IP

Страница 1: ...www panamax com C3 IP Compact IP Power Management C3 IP A BlueBOLT Enabled Compact Power Manager with 3 Outlets Quick Start Guide ...

Страница 2: ... requirements 7 Troubleshooting 8 General Use 8 BlueBOLT Network connectivity 8 C3 IP Specifications 9 Technologies 10 Protect or Disconnect 10 Standard Level RFI EMI Filtration 10 Over Under voltage load disconnect 10 Power Sequencing 10 IP Monitor and Control 10 Warranty information 11 Caution Warranty Limitation for Internet Purchasers 11 Limited three Year Warranty 11 What is Covered 11 Limita...

Страница 3: ...RNING Do not use this apparatus near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 6 CAUTION Could Contain Always On Receptacles depending on BlueBOLT programming To reduce risk of shock Disconnect C3 IP from power source before servicing any equipment connected to C3 IP 7 Clean only with dry cloth 8 Do not install near any heat sources such as...

Страница 4: ...the connected equipment back on sequentially one unit at a time The total output of the 3 AC outlets shall not exceed 12A LIGHTS MOUNTING Use four 10 size screws to mount the C3 IP to a wall or within a structured wiring can A Using any Internet connected computer go to www mybluebolt com using a standard Internet browser B Follow the on screen prompts to add a Location and then to add a Device No...

Страница 5: ...ax signal line protection modules grounds to this terminal Protect data lines as well as AC lines from surges is required for the connected equipment warranty Network Connector Connect an Ethernet cable not provided between the NETWORK port and an Internet router or modem with an established Internet connection for remote control and monitoring Outlet 3 Outlet 2 Network Reset Button Press using a ...

Страница 6: ...reaker is opened or closed and if the Voltage Monitoring is working Power Condition States Normal Input voltage is within range Undervoltage The voltage is so low that the over under voltage load disconnect has engaged and all outlets are off Overvoltage The voltage is so high that the over under voltage load disconnect has engaged and all outlets are off Recovery Recovery 1 Recovering from an ove...

Страница 7: ...create a unique user name and password Input a user name and password and click the Update Login button Password requirements 1 Minimum of 4 characters maximum of 32 characters 2 Case sensitive 3 Comprised of printable characters 4 The word password upper or lower case is not a valid password 5 Passwords of five characters or less may not entirely consist of repetitive characters For example 1111 ...

Страница 8: ... securely installed BlueBOLT Network connectivity Check these steps when having issues with BlueBOLT connectivity Is the C3 IP receiving power Check the power cable and confirm the unit is ON Is the BlueBOLT port on the C3 IP connected to an active local area network with Internet connectivity Check the cables connecting C3 IP to the router switch cables between the router switch and modem and the...

Страница 9: ...rating Control Type 1 Total Current Capacity 12A Maximum Rated Impulse Voltage 1500V Voltage Protection Rating UL1449 L N 500V Initial Clamping Level 200V Peak 141 RMS Energy Dissipation 1680 Joules Peak Impulse Current 12 000 Protect or Disconnect Yes Over voltage load disconnect 140 Vac Under voltage load disconnect 90 Vac Filtration Technology Standard RFI EMI Filtration Filtration Rating 10dB ...

Страница 10: ... video systems will require power sequencing The C3 IP by default is a power sequencer Power sequencing allows A V equipment to be powered up in stages which gives equipment time to stabilize before the next stage of equipment is energized When powering down the sequence order is reversed which results in a soft landing for your expensive A V equipment Power sequencing is also convenient for netwo...

Страница 11: ...TING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other legal rights which vary from State to State How do I Obtain Warranty Service Customers in the United States To obtain wa...

Страница 12: ...have a Return Authorization RA number To get an RA number please call Panamax Tech Support Before returning any equipment for repair please be sure that it is adequately packed and cushioned against damage in shipment and that it is insured We suggest that you save the original packaging and use it to ship the product for servicing Also please enclose a note giving your name address and phone numb...

Отзывы: