10
www.panamax.com
C3-IP Quick Start Guide
TECHNOLOGIES
Protect-or-Disconnect
In the event of a catastrophic surge such as lightning, AC power completely disconnects from connected equipment . If such a rare event occurs, the C3-IP would require
service .
Standard Level RFI/EMI Filtration
The standard level RFI/EMI filter employs a tuned lowpass filter to reduce the differential AC noise coming through your AC power line . The filter reduces the AC line noise on
average 10dB @ 10kHz, 17dB @ 30kHz, 33dB @ 100kHz, 55dB @ 1MHz .
Over/Under voltage load disconnect
The Over/Under voltage load disconnect circuit constantly monitors the incoming line voltage . If the incoming line voltage becomes dangerously high, it will disconnect the load
from the AC input . The high threshold is 140 Vac +/- 2 Vac .
If the incoming line voltage becomes dangerously low, it will disconnect the load from the AC input . The low threshold is 90 Vac +/- 2 Vac .
When the incoming voltage returns to a safe level, the C3-IP will automatically turn on and sequence to its original state before the Over/Under voltage event .
Power Sequencing
Some complicated audio & video systems will require power sequencing . The C3-IP by default is a power sequencer . Power sequencing allows A/V equipment to be powered
up in stages which gives equipment time to stabilize before the next stage of equipment is energized .
When powering down, the sequence order is reversed, which results in a soft landing for your expensive A/V equipment . Power sequencing is also convenient for network
devices that requires network “handshakes” to properly communicate with each other .
After applying power to the AC line input and once you turn the power switch on, outlet 1 will turn on immediately . Outlet 2 will turn on 10 seconds after outlet 1, and outlet 3
will have a 10 second delay from the power on time of the outlet 2 . See defaults below .
Once you claim your C3-IP, you can change the default programing to meet your systems requirements and you have complete flexibility .
IP Monitor and Control
The C3-IP can be monitored and controlled via an internal web page for LAN applications, or you can use the BlueBOLT cloud to monitor, control and program your device from
anywhere in the world via your computer or mobile device .
Outlet Sequence Default
Outlet 1
= 1 second turn on delay, 1 second delay off
Outlet 2
= 10 second turn on delay, 10 second delay off
Outlet 3
= 20 second turn on delay, 20 second delay off