Protect-or-Disconnect

In the event of a catastrophic surge such as lightning, AC power completely disconnects from connected equipment . If such a rare event occurs, the C3-IP would require 
service . 

Standard Level RFI/EMI Filtration

The standard level RFI/EMI filter employs a tuned lowpass filter to reduce the differential AC noise coming through your AC power line . The filter reduces the AC line noise on 
average 10dB @ 10kHz, 17dB @ 30kHz, 33dB @ 100kHz, 55dB @ 1MHz .

Over/Under voltage load disconnect

The Over/Under voltage load disconnect circuit constantly monitors the incoming line voltage . If the incoming line voltage becomes dangerously high, it will disconnect the load 
from the AC input . The high threshold is 140 Vac +/- 2 Vac . 

If the incoming line voltage becomes dangerously low, it will disconnect the load from the AC input . The low threshold is 90 Vac +/- 2 Vac . 

When the incoming voltage returns to a safe level, the C3-IP will automatically turn on and sequence to its original state before the Over/Under voltage event . 

Power Sequencing

Some complicated audio & video systems will require power sequencing . The C3-IP by default is a power sequencer . Power sequencing allows A/V equipment to be powered 
up in stages which gives equipment time to stabilize before the next stage of equipment is energized . 

When powering down, the sequence order is reversed, which results in a soft landing for your expensive A/V equipment . Power sequencing is also convenient for network 
devices that requires network “handshakes” to properly communicate with each other . 

After applying power to the AC line input and once you turn the power switch on, outlet 1 will turn on immediately . Outlet 2 will turn on 10 seconds after outlet 1, and outlet 3 
will have a 10 second delay from the power on time of the outlet 2 . See defaults below . 

Once you claim your C3-IP, you can change the default programing to meet your systems requirements and you have complete flexibility . 

IP Monitor and Control

The C3-IP can be monitored and controlled via an internal web page for LAN applications, or you can use the BlueBOLT cloud to monitor, control and program your device from 
anywhere in the world via your computer or mobile device . 

Outlet Sequence Default

Outlet 1

= 1 second turn on delay, 1 second delay off

Outlet 2

= 10 second turn on delay, 10 second delay off

Outlet 3

= 20 second turn on delay, 20 second delay off

Содержание BlueBOLT C3-IP

Страница 1: ...www panamax com C3 IP Compact IP Power Management C3 IP A BlueBOLT Enabled Compact Power Manager with 3 Outlets Quick Start Guide ...

Страница 2: ... requirements 7 Troubleshooting 8 General Use 8 BlueBOLT Network connectivity 8 C3 IP Specifications 9 Technologies 10 Protect or Disconnect 10 Standard Level RFI EMI Filtration 10 Over Under voltage load disconnect 10 Power Sequencing 10 IP Monitor and Control 10 Warranty information 11 Caution Warranty Limitation for Internet Purchasers 11 Limited three Year Warranty 11 What is Covered 11 Limita...

Страница 3: ...RNING Do not use this apparatus near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 6 CAUTION Could Contain Always On Receptacles depending on BlueBOLT programming To reduce risk of shock Disconnect C3 IP from power source before servicing any equipment connected to C3 IP 7 Clean only with dry cloth 8 Do not install near any heat sources such as...

Страница 4: ...the connected equipment back on sequentially one unit at a time The total output of the 3 AC outlets shall not exceed 12A LIGHTS MOUNTING Use four 10 size screws to mount the C3 IP to a wall or within a structured wiring can A Using any Internet connected computer go to www mybluebolt com using a standard Internet browser B Follow the on screen prompts to add a Location and then to add a Device No...

Страница 5: ...ax signal line protection modules grounds to this terminal Protect data lines as well as AC lines from surges is required for the connected equipment warranty Network Connector Connect an Ethernet cable not provided between the NETWORK port and an Internet router or modem with an established Internet connection for remote control and monitoring Outlet 3 Outlet 2 Network Reset Button Press using a ...

Страница 6: ...reaker is opened or closed and if the Voltage Monitoring is working Power Condition States Normal Input voltage is within range Undervoltage The voltage is so low that the over under voltage load disconnect has engaged and all outlets are off Overvoltage The voltage is so high that the over under voltage load disconnect has engaged and all outlets are off Recovery Recovery 1 Recovering from an ove...

Страница 7: ...create a unique user name and password Input a user name and password and click the Update Login button Password requirements 1 Minimum of 4 characters maximum of 32 characters 2 Case sensitive 3 Comprised of printable characters 4 The word password upper or lower case is not a valid password 5 Passwords of five characters or less may not entirely consist of repetitive characters For example 1111 ...

Страница 8: ... securely installed BlueBOLT Network connectivity Check these steps when having issues with BlueBOLT connectivity Is the C3 IP receiving power Check the power cable and confirm the unit is ON Is the BlueBOLT port on the C3 IP connected to an active local area network with Internet connectivity Check the cables connecting C3 IP to the router switch cables between the router switch and modem and the...

Страница 9: ...rating Control Type 1 Total Current Capacity 12A Maximum Rated Impulse Voltage 1500V Voltage Protection Rating UL1449 L N 500V Initial Clamping Level 200V Peak 141 RMS Energy Dissipation 1680 Joules Peak Impulse Current 12 000 Protect or Disconnect Yes Over voltage load disconnect 140 Vac Under voltage load disconnect 90 Vac Filtration Technology Standard RFI EMI Filtration Filtration Rating 10dB ...

Страница 10: ... video systems will require power sequencing The C3 IP by default is a power sequencer Power sequencing allows A V equipment to be powered up in stages which gives equipment time to stabilize before the next stage of equipment is energized When powering down the sequence order is reversed which results in a soft landing for your expensive A V equipment Power sequencing is also convenient for netwo...

Страница 11: ...TING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other legal rights which vary from State to State How do I Obtain Warranty Service Customers in the United States To obtain wa...

Страница 12: ...have a Return Authorization RA number To get an RA number please call Panamax Tech Support Before returning any equipment for repair please be sure that it is adequately packed and cushioned against damage in shipment and that it is insured We suggest that you save the original packaging and use it to ship the product for servicing Also please enclose a note giving your name address and phone numb...

Отзывы: