background image

i) Damages, malfunctions, or failures caused by operating the unit at water temperatures exceeding the maximum setting of
    the operating, or high limit control.
j) Heat Exchanger failures caused by operating the water heater when it is not supplied with potable water at all times.
k) Damages, malfunctions, or failures caused by subjecting the heat exchanger to pressures, or fi ring rates, greater than 
    those shown on the rating label.
l) Damages, malfunctions, or failures resulting from the use of any attachment, including any energy saving device, not
    authorized by Paloma.
m) Units installed outside the fi fty states (and the District of Columbia) of the United Sates of America and the Dominion 
    of Canada.
n) Units removed from the original installation location and reinstalled elsewhere.
o) Units that have had their rating labels altered, tampered with, or removed. A water heater should not be operated if the
    rating label is removed.
p) This water heater if it is installed for use in: spa or pool heating; a mobile home; a recreational vehicle; a boat or any
    other watercraft.
q) Units installed in any circulating system in which the temperature set point of the water heater is in excess of 120ºF for
    residential models and 140ºF for commercial models.

LABOR, SHIPPING, AND PROCESSING COSTS

For one (1) year after the Effective Date, Paloma will cover reasonable labor costs necessary to repair or replace a tankless 
water heater or component part it determines to be defective in material and/or manufacture by a contractor which is li-
censed, state qualifi ed, and trained for Paloma’s tankless water heater. Except for the above one (1) year labor, this Limited 
Warranty does 

not

 cover any 

labor expenses

 for service, repairs, reinstallation, permits, or removal and disposed of the 

failed water heater, or defective component part(s). All such expenses are your responsibility.
Paloma will pay the 

transportation costs

 for an “In-warranty” replacement water heater, or “In-warranty” replacement 

component part(s), to a convenient delivery point (selected by Paloma) near the place where the original water heater, 
or original component part(s), is located: such as a local Paloma water heater distributor. You must pay any local freight 
charges, including the cost of returning the failed water heater, or defective component part(s) to a convenient shipping 
location (selected by Paloma); such as a local Paloma distributor.
Paloma does 

not

 authorized, recommend, or receive any benefi t from any 

claims processing or similar fees

 charged by 

others to process warranty claims for any Paloma water heater or component part(s). Paloma will 

not

 reimburse any party 

for these, or any other, fees not specifi cally covered in this Limited Warranty document.

HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE

Any claim for warranty assistance must be made promptly. First, determine if your water heater is “In-Warranty” (that is, 
within the Applicable Warranty Period). You can determine your unit’s warranty status by adding its Applicable Warranty 
Period to its date of purchase. However, if you do not have documentary proof of your water heater’s date of purchase, 
your unit’s warranty status will be based on its date of manufacture. The fi rst four digits of the unit’s serial number rep-
resent the month and year it was manufactured. Add the Applicable Warranty Period plus ninety (90) days to the date of 
manufacture to determine whether the water heater is still covered by this Limited Warranty. You may also determine your 
unit’s warranty status by obtaining the complete model number, complete serial number, and date of purchase of your water 
heater and then contacting Paloma at (805) 278-5480 during normal business hours (in the Pacifi c Time Zone) to determine 
if the Applicable Warranty Period has expired.
If your water heater is “In-warranty”, contact the plumber, or mechanical contractor, that installed it for assistance with the 
warranty repairs, or replacement, required. Paloma/Rheem Water Heaters’ 

Technical Service personnel are available to 

assist you (by telephone at (800) 432-8373 or via e-mail at [email protected])

 in obtaining “In-warranty” service 

or to answer your questions about the operation or repair of your water heater during normal business hours (in the Central 
Time Zone). Be prepared to provide the plumber, mechanical contractor, or Paloma/Rheem Technical Service person you 
call with the complete model number, the complete serial number, and the date of purchase of your water heater in addition 
to an explanation of your water heater problem.
If an exact replacement is not available, Paloma will provide you with the current model of your water heater, or compo-
nent part(s), or a replacement unit with comparable operating features. If government regulations or industry certifi cation 
or similar standards require the replacement water heater, or replacement component part(s), to have features not found in 
the defective water heater, or the defective component part(s), you will be charged for the difference in price represented 
by those required features. If you pay the price difference for these required features and/or to upgrade the size and/or other 
features available on a replacement new water heater, you will also receive a complete new Limited Warranty (with the full 
Applicable Warranty Periods) for the replacement new water heater.

38

Содержание PH-28C IFSN

Страница 1: ...r to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very important that all persons who are expected...

Страница 2: ...THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is nee...

Страница 3: ...well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combus...

Страница 4: ...switch adjustment Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is supplying general purpose ho...

Страница 5: ...P gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level l Before attempting to light the water heater make sure to loo...

Страница 6: ...ATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage...

Страница 7: ...which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc l The water heater s...

Страница 8: ...hich may be improperly stored or accidentally spilled l The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for...

Страница 9: ...ghly corrosive after passing through a flame The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere NOTICE The water heater should not be installe...

Страница 10: ...ctions in this manual before completing the installation and putting the water heater into service DANGER Failure to install the appliance vent adapter and properly vent the water heater to the outdoo...

Страница 11: ...he appliance vent adapter manufacturer s instructions A B High Temp Sealant Collar Appliance Vent Adapter Clamp Water Heater Exhaust Flow Draining the Condensate Provision should be made to collect an...

Страница 12: ...de of opening 1 foot 300 mm above opening 6 inches 15 cm for appliances 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 inches 30 cm for appliances 50 000 Btuh 1...

Страница 13: ...d not contain substances that corrode the vent pipe Do NOT extend exposed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Install outdo...

Страница 14: ...alls Reinstall the decorative sheathing around the Wall Thimble This assembly may be painted to match the exterior decor l Attach a Paloma approved 4 10 cm screened 90 elbow termination to the female...

Страница 15: ...to Combustibles Firestop Firestop Roof Jack Adjustable Roof Flashing Vent Adapter 3 8 cm Clearance Support Hanger Condensate Trap To Drain Dispose of condensate in accordance with local codes Storm C...

Страница 16: ...both cold and hot water supply lines DO NOT cover the drain or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed l Operati...

Страница 17: ...ded on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and the water shutoff valve see the top lef...

Страница 18: ...codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T P relief valve or...

Страница 19: ...force over 31 5 ft lbs 42 7 Nm in tightening the pipe particularly if teflon pipe compound is used as the unit may be damaged The inlet gas pressure to the water heater must not exceed 10 5 w c 2 6 k...

Страница 20: ...ust comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22 1 Part 1 20 Installing t...

Страница 21: ...the remote control cables to the extension cable from the water heater l l Place the remote control over the base plate Ensure the projections in the base plate fit into the housings in the remote con...

Страница 22: ...ther equipment that carry a ground fault interrupter l An ON OFF switch must be provided and installed for the incoming 120VAC power l Wire the water heater exactly as shown below A wiring diagram is...

Страница 23: ...l codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions Vacuum Relief Valve Not Supplied If required install per local...

Страница 24: ...ket is to reduce the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover...

Страница 25: ...pply q Gas type matches rating plate q Gas supply pressure is sufficient for the water heater q Gas line equipped with shut off valve union and sediment trap q Approved pipe joint compound used q Soap...

Страница 26: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Страница 27: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Страница 28: ...the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burner if the water heater...

Страница 29: ...d or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply Vacuum a...

Страница 30: ...rner flame Blue flames should be seen when the main burner is firing If any unusual burner operation is noted the water heater should be shut off until qualified service assistance can be obtained CAU...

Страница 31: ...eezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from insta...

Страница 32: ...lfunctions if applicable l Check and replace if necessary Error code displayed on remote control l See instructions for Error Code and if required contact a dealer for service Not enough water demand...

Страница 33: ...material or vent configuration l Open the Gas shutoff valve fully l Contact gas utility company l Fill up LP Gas container or replace with a new cylinder of LP Gas l Bleed all air from gas lines l Ens...

Страница 34: ...late Specify type of gas natural or LP as marked on the rating plate Part description as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring gas...

Страница 35: ...o 120 F 49 C Follow first four bullets points listed above then continue as listed below l Press the SW1 button on the left hand side of the PCB for more than 1 second The LED on the PCB starts illumi...

Страница 36: ...omplete satisfaction you should then contact the following address 2151 Eastman Avenue Oxnard CA 93030 Phone 805 278 5499 When contacting the manufacturer the following information will be requested a...

Страница 37: ...line without the use of a temperature sensor timer or a continuously operating pump All Applicable Warranty Periods will be limited to one 1 year from the Effective Date if the water heater is instal...

Страница 38: ...ter heater or component part s Paloma will not reimburse any party for these or any other fees not specifically covered in this Limited Warranty document HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE Any cl...

Страница 39: ...moved or the date of purchase of the part If it was purchased separately to establish the In warranty status of the defective component part If Paloma determines that the water heater or component par...

Отзывы: