background image

Installing the Main Remote Control:

Electrical Connection

POWER CORD 
(Indoor water heaters only):

l

The electric power supply requirement 
for this water heater is 120 VAC/60HZ, 
2 Amps.

l

The water heater comes with a three (3) pin
power supply cord (INDOOR MODELS
ONLY). Use only a power outlet with a
ground terminal.

l

The installation of an electric leakage
breaker is recommended.

l

Keep any excess of the power supply cord
on the outside of the water heater.

l

If local codes require hardwiring, see
instructions for “Hardwiring the Electrical
Connections”.

HARDWIRING THE ELECTRICAL
CONNECTIONS 
(Indoor or Outdoor water heaters):

l

Wiring should be carried out by a qualified
electrician in accordance with local codes.

l

The water heater requires 120 VAC/60Hz and
should be properly grounded.

l

DO NOT connect grounding wire to water
pipes, gas pipes, telephone cables, lightning
conductor circuits and to grounding circuit
of other equipment that carry a ground-fault
interrupter.

l

An ON/OFF switch must be provided and
installed for the incoming 120VAC power.

l

Wire the water heater exactly as shown
below. A wiring diagram is also found
inside of the cover panel.

l

A green screw is provided in the junction
box (outdoor models only) or in the
enclosure (indoor models only) for 
a grounding connection.

l

Connect the live wire to black leg wire and
the neutral wire to the white neutral wire.

WARNING: Shock

hazard line voltage is
present. Before servicing
the water heater, turn off
the electrical power to the
water heater at the main
disconnect or circuit
breaker. Failure to do so
could result in severe
personal injury or death.

CAUTION: Label 

all wires prior to
disconnection when
servicing controls. Wiring
errors can cause improper
and dangerous operation.
Verify correct operation
after servicing.

BK

8

R GR Y B O W BR

WATER

FLOW

SENSOR

OVER HEAT

LIMITER

BK

GND

GND

THE CONNECTORS OF DUAL AND MULTIPLE

LED

CONTROL

BATH

BATH

CONTROL1

CONTROL2

ARE INTERAPPLICABLE TO THE BODY

CONNECTORS EACH OTHER.(RED)

FLAME ROD1
FLAME ROD2

BK:BLACK

COLOUR CODE

BR:BROWN

R:RED
W:WHITE

B:BLUE
GY:GRAY
GR:GREEN
O:ORANGE
Y:YELLOW
G/Y:GREEN/YELLOW

REMOTE

REMOTE

REMOTE

(UMC-117)

(USC1-117)

(USC2-117)

WIRING DIAGRAM

FUSE(3A)

CIRCUIT

BOARD

W

B

R

O

Y

FUSE

(5A)

U

2

1

S

1

3

2

R

GR

Y

B

O

W

R1

BR

R2

R3

R4

GY

GY

W

Y

R

R

R

BR

W

W

R

W

BK

BK

BK

BK

BK

BK

BK

BK

W

BK

IGNITER

ELECTRODE

1

2

3

4

5

6

7

8

1

2

3

4

R

1

2

3

4

5

6

1

2

3

4

5

6

7

OFF

ON

1 2 3 4

I

H

F

D

E

PSV

M
L

-

+

K

G

CONTROL MOTOR

WATER VOLUME

LIMITER

MOTOR

SW2

SW1

SW3

G/Y

W

AC

120V

1

4
5
6 3

2

3 6

5

2
1 4

IG

B

DIP SWITCH

ADJUSTER

BUTTON

MIN

BUTTON

MAX

BUTTON

MAIN

VA

L

V

E

W

W

W

W

W

W

W

ANTI-FROST

HEATER

(RED)

(RED)

FOR INDOOR,

DIRECT-VENT

MODEL ONLY

CONNECTOR FOR CHECKING

THERMOELECTROMOTIVE FORCE

1

2

1

2

Q

P

TH

ER

M

O

C

O

U

P

L

E

R W

FOR INDOOR,

DIRECT-VENT

MODEL ONLY

GR

GR

WV

WATER BY-PASS
SOLENOID VALVE

USUALLY

DISCON-

NECTED

B

A

USUALLY

DISCONNECTED

31-80469 0

SV2

SV1

SV0

Y

W

R

BK

BK

G/Y

BK

BK

W

W

W

W

J

FM

5

W

Y

B

R

BK

FAN

MOTOR

FOR

DIRECT-VENT

MODEL ONLY

W W

BK BK

FOR

DIRECT-VENT

MODEL ONLY

THERMISTOR

AIR AMBIENT

VA

LVE 0

SOLENOID 

GAS INLET

VA

LVE 1

SOLENOID 

VA

LVE 2

SOLENOID 

RESISTOR

THERMISTOR

INLET W

A

TER

THERMISTOR

EXCHANGER HEA

T

THERMISTOR

HOT W

ATER 

OUTLET

ON

1

2

3

4

DIP1

ON

OFF

1

2

3

4

SW1

SW2

SW3

WARNING: Field wiring connections and electrical grounding must comply with local codes, or

in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70,
or in Canada, Canadian Electrical Code, CSA C22.1 Part 1.

22

Junction Box

(Outdoor

models only)

Содержание PH-16 FISN

Страница 1: ...ater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very important...

Страница 2: ...THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is nee...

Страница 3: ...well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combus...

Страница 4: ...emote control and a dip switch adjustment Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is suppl...

Страница 5: ...P gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level l Before attempting to light the water heater make sure to loo...

Страница 6: ...ATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage...

Страница 7: ...y result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc l The water heater should be...

Страница 8: ...dentally spilled l The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting l The water heater should be...

Страница 9: ...ter heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere NOTICE The water heater should not be installed near an air supply containing halogenated hydroca...

Страница 10: ...service Additional installation information for the Commonwealth of Massachusetts is located on the page 36 of this manual DANGER Failure to install the appliance vent adapter and properly vent the wa...

Страница 11: ...he appliance vent adapter manufacturer s instructions Appliance Vent Adapter Water Heater Exhaust Flow A B High Temp Sealant Collar Clamp Draining the Condensate Provision should be made to collect an...

Страница 12: ...1 foot 300 mm above opening 6 inches 15 cm for appliances 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 inches 30 cm for appliances 50 000 Btuh 15kW K Clearanc...

Страница 13: ...posed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticip...

Страница 14: ...s Reinstall the decorative sheathing around the Wall Thimble This assembly may be painted to match the exterior decor l Attach a Paloma approved 3 7 6 cm screened 90 elbow termination to the female en...

Страница 15: ...vent purchased from the manufacturer Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Roof Jack Adjustable Roof Flashing Vent Adapter 3 8 cm Clearance Support Hanger Condensate Trap...

Страница 16: ...th cold and hot water supply lines DO NOT cover the drain or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed l Operation...

Страница 17: ...Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve be...

Страница 18: ...codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T P relief valve or...

Страница 19: ...use excessive force over 31 5 ft lbs 42 7 Nm in tightening the pipe particularly if teflon pipe compound is used as the unit may be damaged The inlet gas pressure to the water heater must not exceed 1...

Страница 20: ...te controls can connect to the water heater Therefore a maximum of three controls can connect to the water heater No other manufacturer s controls are suitable for use with this water heater DO NOT at...

Страница 21: ...e remote control over the base plate Ensure the projections in the base plate fit into the housings in the remote control l l Fix the control to the base plate at the bottom of the remote control usin...

Страница 22: ...nnection when servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing BK 8 R GR Y B O W BR WATER FLOW SENSOR OVER HEAT LIMITER BK GND GND T...

Страница 23: ...codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions Vacuum Relief Valve Not Supplied If required install per local c...

Страница 24: ...ket is to reduce the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover...

Страница 25: ...pply q Gas type matches rating plate q Gas supply pressure is sufficient for the water heater q Gas line equipped with shut off valve union and sediment trap q Approved pipe joint compound used q Soap...

Страница 26: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Страница 27: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Страница 28: ...otter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burne...

Страница 29: ...nd or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply Vacuum...

Страница 30: ...burner flame Blue flames should be seen when the main burner is firing See figure on page 34 for location of sight glass If any unusual burner operation is noted the water heater should be shut off u...

Страница 31: ...eezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from insta...

Страница 32: ...lfunctions if applicable l Check and replace if necessary Error code displayed on remote control l See instructions for Error Code and if required contact a dealer for service Not enough water demand...

Страница 33: ...erial or vent configuration l Open the Gas shutoff valve fully l Contact gas utility company l Fill up LP Gas container or replace with a new cylinder of LP Gas l Bleed all air from gas lines l Ensure...

Страница 34: ...t connectors or other safety devices Refer repairs to qualified service personnel WARNING For your safety DO NOT attempt to disassemble this unit for any reason Indoor Water Heater Gas Supply Unit Cov...

Страница 35: ...bove then continue as listed below l Press the SW1 button on the left hand side of the PCB for more than 1 second The LED on the PCB starts illuminating continuously At the same time the display of th...

Страница 36: ...time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbo...

Страница 37: ...d to one 1 year from the Effective Date WARRANTY EXCLUSIONS This Limited Warranty will not cover a Service trips to your home to teach you how to install use or maintain this water heater or to bring...

Страница 38: ...rts Paloma determines that a defect exists Paloma shall furnish replacement part s in full settlement of its warranty obligations Purchasers shall be required to return at purchasers expense the defec...

Страница 39: ...This page was intentionally left blank...

Страница 40: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN 31 80171 00...

Отзывы: