INSTALLATION – WATER HEATER
48
Dimensions And Technical Data
Rated delivery
(@ 40
C rise)
litres / min
11.3 12.5
Recovery
(@ 25
C rise)
litres / min
16 20
Mass
Empty
kg
20 20
Gas Details
Test Point Gas Pressure (kPa)
Hourly Gas
Consumption
(MJ)
Min. Gas
Pressure
(kPa)
minimum maximum
Max. Gas
Pressure
(kPa)
016 020
018
to
020
016 020 016 020
016
to
020
Natural
140 153
1.13
0.17 0.170 0.755 0.870
3.50
Propane
140 153
2.75
0.19 0.190 0.930 1.185
3.50
Model numbers: N = Natural, LPG