background image

5

Robata Outdoor Burner Owner and Installation Manual

APPROVED FLEXIBLE GAS HOSE

A.G.A DESIGN-CERTIFIED MANUAL 
SHUTOFF VALVE WITH 1/8” NPT TAP

3” MINIMUM

CAP PIPE NIPPLE TEE JOINT

FROM GAS METER (5” W.C. 
TO 10.5” W.C. PRESSURE)

SEDIMENT TRAP

INSTALLATION REQUIREMENTS

Installation must include a manual shutoff valve, union, 
and plugged 1/8” NPT tap. Locate NPT tap within reach 
for test gauge hook up. NPT tap must be upstream from 
the appliance.

Apply pipe joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. Excess 
sealant in pipe could result in a clogged burner injector.

Install sediment trap in supply line as shown below. 
Locate sediment trap where it is within reach for cleaning 
and trapped matter is not likely to freeze. 

A sediment trap prevents moisture and contaminants 
from entering the Outdoor Fire Pit controls. If a sediment 
trap is not installed, or is installed incorrectly, the unit may 
not work properly.

CHECKING GAS CONNECTION

       WARNING: Test all gas piping and connections 
for leaks after installing or servicing. Correct all leaks 
immediately.

       WARNING: Never use an open flame to check 
for a leak. Apply a mixture of liquid soap and water 
to all joints. Bubbles forming on joints while the 
gas is running indicate a leak. Correct all leaks at 
immediately.

Test Pressures in Excess Of 1/2 psi (3.5 kPa)
This appliance and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of ½ psi (3.5 kPa).

Test Pressures Equal To or Less Than 1/2 psi (3.5 kPa)
This appliance must be isolated from the gas supply 
piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than ½ psi (3.5 
kPa).

CONNECTING TO GAS SUPPLY

 

WARNING:

A qualified service person must 
connect the appliance to the gas 
supply. Follow all local codes.

CAUTION: 
Use only new black iron or steel pipe. 
Internally tinned copper tubing may be 
used in certain areas. Use pipe of 1/2” 
diameter or greater to allow proper 
gas volume to Outdoor Fire Pit Burner. 
If pipe is too small, undue loss of 
pressure will occur.

INSTALLATION ITEMS NEEDED:
Before installing the Outdoor
Fire Pit, make sure you have all items 
listed bellow:
• 

piping (check local codes)

• 

sealant

• 

manual shutoff valve

• 

adjustable (crescent) wrench or pliers

• 

sediment trap

• 

tee joints

• 

pipe wrench

                 

 

Содержание ROBATA ROB-36

Страница 1: ...he appliance and immediately call your gas supplier or fire department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP c...

Страница 2: ...rom combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children...

Страница 3: ...tep 7 Carefully lift the burner and place it in its housing See page 4 8 Place and evenly distribute decorative topping media lava rock or broken tempered glass on top of burner media as shown in pict...

Страница 4: ...ed in any non combustible materials This is an example not a requirement NON COMBUSTIBLE MATERIALS ONLY complete structure Allow for air flow from below Min 8 square inches per foot of burner Maintain...

Страница 5: ...flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in...

Страница 6: ...R PORTS PORT SIZE ROB 36 60 000 4 5 W C 10 5 W C 3 5 W C 26 16 1 8 ROB 48 80 000 4 5 W C 10 5 W C 3 5 W C 18 22 1 8 ROB 36P 57 000 11 0 W C 13 0 W C 10 0 W C 43 16 1 8 ROB 48P 77 000 11 0 W C 13 0 W C...

Страница 7: ...any gas control that has been under water Improper installation adjustment alteration service or maintenance can result in injury or property damage For assistance or additional information consult a...

Страница 8: ...to the ON position 7 Plug the supplied 7V DC adapter into a 110V power outlet 8 Connect the wire to the DC input plug at the unit 9 Replace the Heat Shield and Top Tray 10 Turn on electric power to t...

Страница 9: ...gs are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner The burner must be replaced prior to the appliance being put...

Страница 10: ...to allow more flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing Burner is excessively noisy Note The movement and combustion of gas will create low...

Страница 11: ...lean pilot see Cleaning and Maintenance page 9 or replace pilot assembly 5 Replace ignitor Burner does not light after pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 3 Burner...

Страница 12: ...onnector Adapter DC 7V 10 mA Burner Media Topping Media 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PKG PKG LBN036 LBC001 LBC002 LBC036 LBC003 LBC004 EPS001 EPC001 EPC002 OAM026 N A FP0001 FP0002 FC0001 G...

Страница 13: ...13 Robata Outdoor Burner Owner and Installation Manual ILLUSTRATED PARTS LIST cont d 1 2 3 7 9 8 10 11 12 12 13 15 21 16 17...

Страница 14: ...14 Robata Outdoor Burner Owner and Installation Manual ILLUSTRATED PARTS LIST ProFlame Wiring Diagram...

Страница 15: ...Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burne...

Отзывы: