Paloform Fold 48-E LP Corten Скачать руководство пользователя страница 8

8

FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual

CONNECTING TO GAS SUPPLY

 

WARNING:

A qualified service person must connect 
the appliance to the gas supply. Follow all 
local codes.

CAUTION: 

Use only new black iron or steel pipe. 
Internally tinned copper tubing may be 
used in certain areas. Use pipe of 1/2” 
diameter or greater to allow proper gas 
volume to Outdoor Fire Pit Burner. If pipe 
is too small, undue loss of pressure will 
occur.

INSTALLATION ITEMS NEEDED:

Before installing the Outdoor
Fire Pit, make sure you have all items 
listed bellow:
• 

piping (check local codes)

• 

sealant

• 

manual shutoff valve

• 

adjustable (crescent) wrench or pliers

• 

sediment trap

• 

tee joints

• 

pipe wrench

 

INSTALLATION REQUIREMENTS

This appliance must be installed and serviced by trained 
gas installation and service technician only. All pipework 
must be supported and installed in accordance with local 
and/or national regulations.

• 

The gas supply to the appliance must terminate 
with an isolation cock and a flexible connector. 
This will allow the appliance to be disconnected for 
maintenance or repair. The appliance is supplied with 
a 1/2” BSP male pipe fitting.

• 

Check that the main gas supply line is of proper 
diameter to supply the required fuel pressures. Pipes 
of a smaller size than the heater inlet gas connection 
must not be used.

• 

If utilizing used pipe, verify that its condition is clean 
and comparable to a new pipe. Test all gas supply 
lines in accordance with local codes.

• 

Test and confirm that inlet pressures are correct. 
Refer to the heater data plate and packaging to verify 
fuel type.

• 

Install a sediment trap/drip leg for condensation 
which may occur at any point of the gas supply line. 
This will decrease the possibly of loose scale or dirt 
in the supply line entering the appliance’s control 
system and causing a malfunction.

CHECKING GAS CONNECTION

       WARNING: Test all gas piping and connections 
for leaks after installing or servicing. Correct all leaks 
immediately.

       WARNING: Never use an open flame to check for 
a leak. Apply a mixture of liquid soap and water to all 
joints. Bubbles forming on joints while the gas is running 
indicate a leak. Correct all leaks at immediately.

Test Pressures in Excess Of 37 mbar
This appliance and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 37 mbar.

Test Pressures Equal To or Less Than 37 mBar
This appliance must be isolated from the gas supply 
piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 37 mbar.

Содержание Fold 48-E LP Corten

Страница 1: ...carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment al...

Страница 2: ...fixed piping system The installation must conform to local and or national codes 3 Never leave the fire unattended 4 Keep the appliance area clear and free from combustible materials gasoline and oth...

Страница 3: ...te and weather conditions Rust will bleed until it stabilizes Do not place Cor Ten fire pits on surfaces that will be permanently damaged or stained by rust bleed METAL COVER 1 UNPACK Account for all...

Страница 4: ...r Model CIR E 18 CIR E 18P Nominal Heat Input G20 20mbar 25 kW G31 37mbar 25 kW 1770 gr h Burner Pressure 8 7 mbar 25 mbar Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 3 mm 1 8 3 mm Electrical...

Страница 5: ...5 FOLD 48 FIRE TABLE CE Electronic Ignition Installation Owner s Manual MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 6 72 72 6 1829 mm 152 mm...

Страница 6: ...safe distance during this time LIGHTING PORT DO NOT OBSTRUCT CORRECT FLAME APPEARANCE BURNER MEDIA DECORATIVE TOPPING TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply u...

Страница 7: ...ual BURNER MEDIA DECORATIVE TOPPING METAL TABLE TOP DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER...

Страница 8: ...uel pressures Pipes of a smaller size than the heater inlet gas connection must not be used If utilizing used pipe verify that its condition is clean and comparable to a new pipe Test all gas supply l...

Страница 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or...

Страница 10: ...ce including near the floor If you smell gas STOP Follow the instructions on page 1 of this manual If you do not smell gas continue to the next step 6 Turn the manual gas control valve to the ON posit...

Страница 11: ...ILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover t...

Страница 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is s...

Страница 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pi...

Страница 14: ...same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18 FIT...

Страница 15: ...using CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Cont...

Страница 16: ...gram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT PIL E 410 OR PIL E 410LP IGNITION CON...

Страница 17: ...y will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by acc...