Paloform Fold 48-E LP Corten Скачать руководство пользователя страница 11

11

FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual

CLEANING AND MAINTENANCE

KEEP YOUR FIRE PIT COVERED

Covering your fire pit with its all-weather cover when not in use will prolong the life of 
all its components.

WARNING: Turn off gas before servicing fire pit. 

We recommend that a qualified service technician perform the following 
check-ups at the beginning of each fire pit season.

If any irregularities are apparent with operation. Please refer to Troubleshooting guide, 
pages 12-13.

BURNER ELEMENT AND PILOT

Keep the burner and pilot area clean by vacuuming or brushing at least twice a year. 
Make sure the burner porting and burner air openings are free of obstructions at all 
times. Remove pilot cover to inspect pilot.

Remove topping from top of burner ring and Inspect area around the burner. Remove 
any lint or foreign material with a brush or vacuum cleaner.

PILOT FLAME

The flames from the pilot should be 
visually checked as soon as the unit is 
installed, and periodically during normal 
operation.  The pilot flame must always be 
present when the fire pit is in operation.  
The pilot flame has two distinct flames:  
one engulfing the flame sensor and the 
other reaching to the main burner.

BURNER ELEMENT

PILOT ASSEMBLY

FLAME SENSOR

Содержание Fold 48-E LP Corten

Страница 1: ...carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment al...

Страница 2: ...fixed piping system The installation must conform to local and or national codes 3 Never leave the fire unattended 4 Keep the appliance area clear and free from combustible materials gasoline and oth...

Страница 3: ...te and weather conditions Rust will bleed until it stabilizes Do not place Cor Ten fire pits on surfaces that will be permanently damaged or stained by rust bleed METAL COVER 1 UNPACK Account for all...

Страница 4: ...r Model CIR E 18 CIR E 18P Nominal Heat Input G20 20mbar 25 kW G31 37mbar 25 kW 1770 gr h Burner Pressure 8 7 mbar 25 mbar Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 3 mm 1 8 3 mm Electrical...

Страница 5: ...5 FOLD 48 FIRE TABLE CE Electronic Ignition Installation Owner s Manual MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 6 72 72 6 1829 mm 152 mm...

Страница 6: ...safe distance during this time LIGHTING PORT DO NOT OBSTRUCT CORRECT FLAME APPEARANCE BURNER MEDIA DECORATIVE TOPPING TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply u...

Страница 7: ...ual BURNER MEDIA DECORATIVE TOPPING METAL TABLE TOP DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER...

Страница 8: ...uel pressures Pipes of a smaller size than the heater inlet gas connection must not be used If utilizing used pipe verify that its condition is clean and comparable to a new pipe Test all gas supply l...

Страница 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or...

Страница 10: ...ce including near the floor If you smell gas STOP Follow the instructions on page 1 of this manual If you do not smell gas continue to the next step 6 Turn the manual gas control valve to the ON posit...

Страница 11: ...ILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover t...

Страница 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is s...

Страница 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pi...

Страница 14: ...same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18 FIT...

Страница 15: ...using CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Cont...

Страница 16: ...gram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT PIL E 410 OR PIL E 410LP IGNITION CON...

Страница 17: ...y will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by acc...