WARNING:

Turn off appliance and let cool before 
servicing.  Only a qualified service person 
should service and repair this appliance.

TROUBLESHOOTING cont’d

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When power is turned on, nothing 
happens

1. 

No power to unit

1. 

Check connections between 
controls, power adapter and 
power source

2. 

Check power at source

3. 

Verify that power adapter is 
functioning correctly

4.  If you are using a third-party 

remote control unit, verify that 
this unit is functioning correctly

When power is turned on, there is a 
spark at pilot but no ignition

1. 

Gas supply turned off or manual 
shutoff valve closed

2. 

Air in gas lines when installed

3. 

Pilot is clogged

4.  Pilot valve lead is loose/

disconnected

1. 

Turn off gas supply or open 
manual shutoff valve

2. 

Purge air from the supply line

3. 

Clean pilot 

(see Cleaning and 

Maintenance, page 11)

 or replace 

pilot assembly

4.  Check/reconnect lead

Burner does not light after pilot is lit

1. 

Burner orifice is clogged

2. 

Inlet gas pressure is too low                  

3. 

Flame sensor or Main Valve lead 
loose/disconnected

4.  Ignition Control Board failure

1. 

Clean burner orifice

2. 

Contact local gas or propane 
supplier

3. 

Reconnect / replace lead 

4.  Replace Board

Delayed burner ignition

1. 

Lighting port is blocked

1. 

Remove burner media/debris 
from Lighting Port

Burner flame is too low or too high

1. 

Incorrect gas supply or pressure

2. 

Blocked burner orifice or burner 
ports

3. 

Improper burner orifice size

1. 

Check for proper gas supply 
pressure

2. 

Free burner orifice and burner 
ports of any burrs, paint, or other 
blockage

3. 

Verify proper burner orifice sizing 

(see page 4)

Содержание Fold 48-E LP Corten

Страница 1: ...carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment al...

Страница 2: ...fixed piping system The installation must conform to local and or national codes 3 Never leave the fire unattended 4 Keep the appliance area clear and free from combustible materials gasoline and oth...

Страница 3: ...te and weather conditions Rust will bleed until it stabilizes Do not place Cor Ten fire pits on surfaces that will be permanently damaged or stained by rust bleed METAL COVER 1 UNPACK Account for all...

Страница 4: ...r Model CIR E 18 CIR E 18P Nominal Heat Input G20 20mbar 25 kW G31 37mbar 25 kW 1770 gr h Burner Pressure 8 7 mbar 25 mbar Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 3 mm 1 8 3 mm Electrical...

Страница 5: ...5 FOLD 48 FIRE TABLE CE Electronic Ignition Installation Owner s Manual MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 6 72 72 6 1829 mm 152 mm...

Страница 6: ...safe distance during this time LIGHTING PORT DO NOT OBSTRUCT CORRECT FLAME APPEARANCE BURNER MEDIA DECORATIVE TOPPING TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply u...

Страница 7: ...ual BURNER MEDIA DECORATIVE TOPPING METAL TABLE TOP DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER...

Страница 8: ...uel pressures Pipes of a smaller size than the heater inlet gas connection must not be used If utilizing used pipe verify that its condition is clean and comparable to a new pipe Test all gas supply l...

Страница 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or...

Страница 10: ...ce including near the floor If you smell gas STOP Follow the instructions on page 1 of this manual If you do not smell gas continue to the next step 6 Turn the manual gas control valve to the ON posit...

Страница 11: ...ILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover t...

Страница 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is s...

Страница 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pi...

Страница 14: ...same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18 FIT...

Страница 15: ...using CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Cont...

Страница 16: ...gram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT PIL E 410 OR PIL E 410LP IGNITION CON...

Страница 17: ...y will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by acc...

Отзывы: