Install an MPC Logging Drive
STEP 1 |
Attach an ESD strap to your wrist and plug the other end in to the ESD port location on the
front of the appliance. See
for the location of the ESD port.
STEP 2 |
Loosen the retaining screw on the logging drive blank cover while gently pulling on the pull tab.
Proceed until the logging drive blank cover can be pulled out from the MPC faceplate.
STEP 3 |
Insert the logging drive into the opening in the MPC faceplate. Align the retainer screw with
the threaded hole in the MPC faceplate.
STEP 4 |
Once the logging drive is fully seated, tighten the retainer screw to 4 in-lbs.
Exceeding a torque of 4.5 in-lbs will damage the equipment.