| Pallas RO500
INSTALLATION AND REPLACEMENT OF MEMBRANE
1. Disconnect the plug from the socket.
2. Turn off the water supply valve.
3. Turn the Jaco fittings clockwise.
4. Unscrew membrane housing’s cap by turning it
clockwise.
5. Grasp the membrane with a clamp and pull out.
6. Push new membrane carefully into the housing
until it stops.
After installing the membrane, screw the cap and
reinsert the tube in the same way. Open RO tap to
clean the newly installed membrane filter. Let the
system run for 2 hours and the water run out. Then,
you can drink the purified water.
Membrane replacement and housing
sanitisation as seen in figures;
Open drinking water faucet.
Loose the union of the membrane housing on
the water inlet side and disconnect tubing from
the housing.
Unscrew the membrane housing from the cap
(with pliers) and displace the used membra-
ne.-Clean the membrane housing with disinfe-
ctant (bleach solution) and rinse the housing.
Wet or wipe the O-ring at the bottom of thenew
membrane element for being seated properly.
Push the membrane into the housing with o-ring
side first. Ensure the membrane fit into the hou-
sing properly.
Screw the cap back onto the membrane housing
and tighten with hand or the supplied wrench.
Finally, place the union at the water inlet side of
the membrane properly and tighten firmly.
1. Open the tube union of 3rd housing and dischar-
ge the water supplied to Sedimentfilter, Activa-
ted Carbon filter and BlockCarbon filter. Perform
washing for 10 minutes.
2. First three filters are washed. If post-carbonand
mains pressure are present, mineral filter iswas-
hed with the mains pressure for 10 minutes.
Wastewater is discharged from the faucet.
3. The membrane filter is pushed in the housing
with the O-ring side first and the housing cap
is screwed. Water is supplied to the membrane.
The water first-supplied to the membrane should
be flown out without reaching the tank and the
post carbon. The water should be drained for 10
min.
WASHING PROCEDURES
Do not forget to connect the power plug to the socket in
models with pump.
The treatment device must not be supplied with hot water. Oth-
erwise, all filters will be damaged and the device will be out of
warranty.
The water first-supplied to the device should be discharged
after passing through the filters. It should definitely not contact
the tank and post carbon
!! ATTENTION !!
To RO system