background image

UH239

UH239 Series

service 

instructions

EN

U H 2 3 9   S e r v i c e   I n s t r u c t i o n s

ENGLISH

UK62959

IMSIUH239

Содержание UH239 Series

Страница 1: ...UH239 UH239 Series service instructions EN UH239 Service Instructions ENGLISH UK62959 IMSIUH239 ...

Страница 2: ...mm 20 5in for length 20 housings 4 2 2 The UH239 filter housing is supplied without a filter element For filter element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when fitted must be torque tightened up to 38 ft lb or 54 Nm All visual indicators must be clearly visible NOTE The UH239 filter head is supplied with two machined differential pre...

Страница 3: ...e when the filter element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 16 reset by depressing the button when the normal operating temperature is reached If indicator actuates after resetting replace element NOTE Option P visual indicator has thermal lockout and manual reset No s...

Страница 4: ...f the system into which the filter is installed 4 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must not be carried out when a potentially explosive atmosphere is present Refer to Service Parts List Section 9 for...

Страница 5: ... of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in use storage tra...

Страница 6: ...UH239 UH239 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 3 9 4 Figure 2 7 Inlet 5 6 1 8 Not shown on this diagram Not shown on this diagram Outlet ...

Страница 7: ...UH239 UH239 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Страница 8: ...s in your area please go to www pall com corporate_contact asp Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Copyright 2008 Pall Corporation Pall and are trademarks of Pall C...

Отзывы: