Pall UH239 Series Скачать руководство пользователя страница 3

UH239

UH239 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

3

4.8

Bleed the UH239 filter assembly by opening the vent
plug (7) at the top of filter one and one half turns. Jog
system and fill filter until all air bleeds through the plug,
then torque tighten the vent plug to 12 ft/lb or 16 Nm.

Pressurize system fully and check for leaks; if leaks occur 
refer to section 5.

5

Routine maintenance

5.1

Pall

filter assembly’s do not normally require special

attention except for periodic monitoring of the differential
pressure warning device. Schedule replacement of the
filter element every six months or sooner, and have ample
supply of spare elements available.

5.2

If external leakage is noted, replace O-ring at leak. If
leakage persists, check sealing surfaces for scratches 
or cracks; replace any defective parts. 

5.3

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. If 'cold start' conditions exist, 
see Section 6.2 and 6.3.

5.4

A dirty system can quickly plug a new filter element,
especially with 

Pall

high efficiency filter media. It may

require one or two initial filter element changes to
stabilize element service life. If element service life is
short or differential pressure is excessive, the filter
assembly may be undersized; refer to the sizing and
selection section of the product literature or contact your
local Pall representative.

5.5

Make sure element change labels are clean and
undamaged. Replace illegible labels with the 
appropriate new labels.

6

Differential pressure devices

Reference should be made to product literature for dimensions,
operating parameters, part numbering, ordering information
and specifications. 
6.1

Differential pressure devices actuate when the filter
element needs changing or because of high fluid
viscosity in 'cold start' conditions. 

6.2

If visual indicator is fitted and actuates during 'cold start'
(red button extends 5mm, 3/16"), reset by depressing the
button when the normal operating temperature is reached.
If indicator actuates after resetting, replace element. 

NOTE: Option 'P' visual indicator has thermal lockout and
manual reset. No signal below 0°C (32°F), signal above 
29°C (80°F).

6.3

If the electrical switch actuates (e.g. red light comes on)
during cold start, continue operating until the signal (red
light) goes out as system warms to normal operating
temperature. This feature can be used as 'warm up'
indication in operating procedures. If the warning signal
(red light) remains or appears when system is warm,
replace the filter element.

ENGLISH

6.4

Use of both positive indication (green light) and negative
indication (red light for dirty element) is recommended to
effectively monitor filter element life.

Electrical connections and ratings for all differential
pressure switch options:

110 VAC

=

4A (inductive),
4A (resistive)

220 VAC

=

4A (inductive),
4A (resistive)

28 VDC

=

3A (inductive),
5A (resistive)

48 VDC

=

1A (inductive),
1.5A (resistive)

125 VDC

=

0.25A (inductive),
0.5A (resistive)

Maximum inrush - 24 amps.
Underwriter’s lab. Inc. listed ratings of pressure switch
(Microswitch) options are:
4 amps at 250 VAC
0.25 amp resistive at 220 VDC
0.50 amp resistive at 110 VDC

Electrical differential pressure switch operation:

When preset differential pressure is exceeded continuity
switches from 'C' - 'A' to 'C' - 'B'.
When differential pressure decreases below the pre-set value,
continuity returns to 'C' - 'A'.

Figure 1 

- Switch Circuit Diagram

C
or black
or tag 2

CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.

A
or white
or tag 1

B
or red
or tag 3

LOW DIFFERENTIAL PRESSURE

HIGH DIFFERENTIAL PRESSURE

Содержание UH239 Series

Страница 1: ...UH239 UH239 Series service instructions EN UH239 Service Instructions ENGLISH UK62959 IMSIUH239 ...

Страница 2: ...mm 20 5in for length 20 housings 4 2 2 The UH239 filter housing is supplied without a filter element For filter element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when fitted must be torque tightened up to 38 ft lb or 54 Nm All visual indicators must be clearly visible NOTE The UH239 filter head is supplied with two machined differential pre...

Страница 3: ...e when the filter element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 16 reset by depressing the button when the normal operating temperature is reached If indicator actuates after resetting replace element NOTE Option P visual indicator has thermal lockout and manual reset No s...

Страница 4: ...f the system into which the filter is installed 4 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must not be carried out when a potentially explosive atmosphere is present Refer to Service Parts List Section 9 for...

Страница 5: ... of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in use storage tra...

Страница 6: ...UH239 UH239 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 3 9 4 Figure 2 7 Inlet 5 6 1 8 Not shown on this diagram Not shown on this diagram Outlet ...

Страница 7: ...UH239 UH239 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Страница 8: ...s in your area please go to www pall com corporate_contact asp Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Copyright 2008 Pall Corporation Pall and are trademarks of Pall C...

Отзывы: