13.6
Circuit Breaker(s) Inside Enclosure
Circuit breakers are preinstalled inside the Hydraulic Enclosure. The ON/OFF switch is connected to the circuit
breaker(s) with a bus bar. Installing the power cable to ON/OFF switch is the same for single and dual pump
and motor configurations. Reference Section 13.7 for wiring truck or trailer configurations.
Secondary
Pump & Motor
Power Cable
Primary
Pump & Motor
Power Cable
Circuit
Breakers
Circuit
Breaker
Primary
Pump & Motor
Power Cable
Dual Pump & Motor Circuit Breaker Configuration
Single Pump & Motor Circuit Breaker Configuration
Power Cable
(To Batteries)
Power Cables
(To Batteries)
ON/OFF
Switch
ON/OFF
Switch
Dual Circuit Breaker
Suggested Wiring
Circuit
Breaker
Power
Cable
Jumper
Ground Cable
From Motor
Ground Cable
From Vehicle
Power
Cable
Jumper
Power
Cable
Jumpers
Power
Cable
Jumper
Circuit
Breakers
Single Circuit Breaker
Suggested Wiring
Power Cable
From Motor
Power Cable
From Motor
Ground Cable
From Vehicle
Ground Cable
From Motor
Knockouts
Grommets for Knockouts
tied to battery wire
Knockouts
Grommets for Knockouts
tied to battery wire