PTV 35/44/55/66 Installation Manual
Rev. 1.1
48
4.
Installing 1/4
” and 3/8” Hoses at Right Side Column: Install hoses to the hydraulic block.
Torque 1/4
”
hoses to 11 ft/lbs. max, and 3/8
” hoses to 19 ft/lbs. max.
Note: Mark or label each hose end with the corresponding Port ID letter before routing to facilitate
installation at the hydraulic enclosure side.
Recommended
Optional - When vehicle design does
not permit the installation of hydraulic
fittings. Connecto hoses directly to
valve block fittings.
5.
Installing Hoses at Hydraulic Enclosure: Remove the plugs and caps,
Fig. 16
, from the side of the
hydraulic pump and motor (enclosure).
Hat Section
Hoses from
Column
Caps
Plug
Plug
Route the hoses coming from the column over to the hydraulic enclosure,
Fig.17
. Route along the enclosure
frame. When routing hoses never make sharp bends, maintain a natural hose radius. Connect the hoses from
the hydraulic block to the pump & motor (hydraulic enclosure) corresponding ports,
Fig 18
. Use zip ties to
secure the routed hoses to the mounting frame.
Torque 1/4
” hoses to 11 ft/lbs. max, and 3/8” hoses to
19 ft/lbs. max.
Hydraulic Fittings on
Side of Enclosure
Hoses from
Hydraulic
Junction Block
Secure Hoses
with Zip Ties
A
B
C
D
Port Identification
Fig. 16
Fig. 18
Fig. 17