6.3.2
Checking and Changing the Oil
Check the quality of hydraulic fluid. Take the following steps to change the oil. In stored position, lower gate to
ground (for Easy move model keep gate in stored position) and remove lock bolt. Pull the power pack out until
you can reach the oil filler cap. Unscrew the oil drainage bolt (bottom of tray) and let the fluid drain out of the
reservoir into an approved container. If the reservoir is empty fill it up with hydraulic oil, as shown on table 2.
Figure 6: Power Pack (Side View)
Figure 7: Power Pack (Top View)
6.3.3
Recommended Hydraulic Fluids
TEMP. RANGE
BRAND
-10 TO 150 F
EXXON
UNIVIS J26
MOBIL OIL
DTE 13M
CHEVRON
AW MV32
ROSEMEAD
MV 150 (32)
-50 TO 150 F
MOBIL
DTE 13M
SHELL
AERO FLUID 4
EXTREME COLD TEMPERATURE:
USE MILITARY SPEC:
MIL H5606
Table 2: Recommended Hydraulic Fluids
Hydraulic
connections
Suction filter
in oil tank
Oil filler cap
S5 Shift valve
Motor Studs
Motor Solenoid
Pressure Gauge plug
Below valve block:
Oil drainage screw 6mm hexagon socket
Tray lock bolt
Oil reservoir clamp
Pressure adjustment valve
Positive Stud
Ground