6.3
SMOKE EXHAUST SYSTEM
The Ecomonoblocco must be connected to a smoke
exhaust system so as to ensure combustion products are
suitably discharged into the atmosphere, in accordance
with standards EN 1856-1-2 EN 1857, EN 1443 EN
13384-1-3, EN 12391-1 and UNI 10683, both as regards
sizing and the construction materials used.
• CHIMNEY draught must be sized as described on
the datasheet.
• The components making up the combustion
product exhaust system must be declared as being
VXLWDEOHIRUWKHVSHFL¿FRSHUDWLQJFRQGLWLRQVDQG
marked (declaration of conformity or European
technical approval for the product).
• The
À
ue must have a constant cross-section along
its entire height.
• A collection chamber should be featured
a t t h e b o t t o m o f t h e f l u e t o c o l l e c t
any solid residues and condensate.
IMPROVISED
À
ues made using unsuitable materials
are illegal and affect correct operation of the
Ecomonoblocco.
• A
PERFECT DRAUGHT
is above all the result of
a
À
ue that is clear of obstructions such as chokes,
horizontal sections or corners; any axial displacements
should be at a maximum angle of 45° compared to
the vertical axis, (better still if it is only 30°). These
displacements should preferably be effected near the
chimney top (Fig. 6.5).
• The
SMOKE
connection between the
¿
replace and
flue should have the same cross section as the
stove’s smoke outlet. The smoke
¿
tting must be sealed
and the use of
À
exible metallic pipes is prohibited.
Changes in direction in respect to the smoke outlet
of the appliance must be executed using elbows not
exceeding 45° in respect to vertical.
• The
CHIMNEY TOP
shall be the
WINDPROOF
type
with an inside cross section equivalent to that of the
À
ue and with a smoke outlet passage section at least
DOUBLE
the internal one of the
À
ue.
• To avoid draught problems, each stove should have
its own
À
ue. If there is more than one
À
ue on the roof
the others should be situated at a distance of at least 2
metres and the stove’s chimney top should be at least
40 cm ABOVE the others (Fig. 6.4). If the chimney
tops are near each other install some dividing panels.
• Fig. 6.6 (FLAT ROOF; B service compartment) and
Fig. 6.7 (SLOPING ROOF; B above the ridge) show
suggestions on the minimum distances and chimney
top positions.
• If the stove is installed with a
À
ue that has already
been used it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
deposited on the inside from catching
¿
re.
• Under normal conditions of use of the stove the
À
ue
should be cleaned at least once a year or after 40
quintals of wood have been burnt, unless regulations
state otherwise except for different regulations.
C
ONSIGLI
Recommendations - Beratung
:
C
OMIGNOLI
,
DISTANZE
E
POSIZIONAMENTO
Chimney tops, distances and positioning;Schornsteine, Abstände und Positionierung
Inclinazione del tetto
Roof slant
Neigung des Dachs
Distanza colmo-camino
Distance ridge cap-chimney
Abstand Dach
¿
rst und Kamin
altezza min del camino (dallo
sbocco)
minimum chimney height
Mindesthöhe des Kamins
Į
A[m]
H[m]
15°
< 1,85
0,5 oltre il colmo; above the ridge of
the roof; über den Dach
¿
rst
> 1,85
1 dal tetto; from the roof; vom Dach
30°
< 1,5
0,5 oltre il colmo; above the ridge of
the roof; über den Dach
¿
rst
> 1,5
1,3 dal tetto; from the roof; vom
Dach
45°
< 1,3
0,5 oltre il colmo; above the ridge of
the roof; über den Dach
¿
rst
> 1,3
2 dal tetto; from the roof ; vom
Dach
60°
< 1,2
0,5 oltre il colmo; above the ridge of
the roof; über den Dach
¿
rst
> 1,2
2,6 dal tetto; from the roof; vom
Dach