6
POWER UNIT SPECIFICATIONS
IMPORTANT
Exceeding any of the maximum recommended power unit specifications
CAN result in damage to this product and
WILL void all FFC Attachments warranties.
DESCRIPTION SPECIFICATIONS
Hydraulic Flow Output
25 gpm. Maximum
Hydraulic Pressure Output
2,500 psi. maximum (continuous)
3,500 psi. maximum (intermittent: no more than 6 seconds per minute)
Rear or Front Ballast
As required to maintain full power unit stability. (Note the Shipping Weight
on Specifications page, then see the operators manual(s) for your power
unit, loader, and quick-attach for ballasting needs.)
PREPARATOR
®
MOUNTING
SAFETY FIRST!! READ AND UNDERSTAND THE SAFETY INSTRUCTIONS (pages
2-5 of this manual) BEFORE BEGINNING ANY PREPARATOR
®
MOUNTING
Loaders
1. Place this product on a firm, level surface that is large enough to safely accommodate this product, your power unit
and all workers involved in the mounting process.
2. Refer to the operator’s manual(s) for your power unit, loader, and quick-attach and follow the mounting instructions
contained therein.
3. Carefully raise the loader and cycle the tilt cylinders to check clearances and to verify that all mounting procedures
have been successfully completed.
4.
IMPORTANT
Lubricate all grease fittings before connecting this product to your power unit’s hydraulic
system. Refer to PREPARATOR
®
MAINTENANCE page and follow the instructions.
3 Point Hitch Category 1 or 2.
1. Place this product on a firm, level surface that is large enough to safely accommodate this product, your tractor, and
all workers involved in the mounting process. Making sure this product is in the operating position and level will
facilitate in selecting the proper mounting holes.
2. Read and understand the Operation and Maintenance manual for your tractor before installing this product.
3. Remove the top link on your tractors’ 3 point and drive the tractor backwards in to position to connect the lower links
to the attachment mounting ears. The ears have a combination category 1 & 2 hitch pin installed so you need to
make sure the outer pin matches your tractors’ category. Select a hole position on the mounting ears that aligns or is
a little above the lower link points with the tractor link arms fully lowered and connect the arms.
4. The upper link cylinder provided with this product requires a category #2, 1” diameter pin to attach to the tractors’
upper link point. If you have a category #1 tractor you will have to bush the pin up to category #2
. It is important
that when you pin the rod end of the cylinder to the tractors’ upper link point there is between 4” and 5” of
exposed cylinder rod
. If you have less the bucket will not roll back enough and if you have more the bucket will not
dump properly. Move the cylinder pin hole position on the mounting ears until you attain the recommended amount of
exposed cylinder rod.
5.
IMPORTANT
Lubricate all grease fittings before connecting this product to your power unit’s hydraulic
system. Refer to PREPARATOR
®
MAINTENANCE page and follow the instructions.