150-231-184-05, Revision 05
Appendix A - Specifications
HLU-231 List 8D
October 25, 1999
51
Power Consumption with Doublers
through
list the power consumed and dissipated by the HLU-231 List 8D when it is used with
any of the four basic doubler types in the HiGain family. The maximum current drawn by the CO supply is also
listed.
through
shows power parameters for single doubler, line-powered circuits on 9 kft, 26 AWG
loops.
Table 17.
Power Parameters—Single Doubler (HDU-451 List 1 or 2)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
27.5
30.3
7.6
8.4
646
711
HRU-412 List 1, 2, 3, 4
OFF
25.9
28.5
7.2
7.9
610
671
HRU-412 List 6, 7, 8
ON
27.7
30.5
7.6
8.4
651
716
HRU-412 List 6, 7, 8
OFF
24.3
26.7
7.1
7.8
571
628
HRU-402
N/A (OFF)
21
23.1
6.3
6.9
494
543
HRU-411
OFF
20
22.0
6.2
6.8
471
518
Table 18.
Power Parameters—Single Doubler (HDU-439 or HDU-437 Lists 1 and 1B)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
22.3
24.5
7.9
8.6
525
578
HRU-412 List 1, 2, 3, 4
OFF
21.4
23.5
7.8
8.5
502
552
HRU-412 List 6, 7, 8
ON
22.3
24.5
8.0
8.8
524
576
HRU-412 List 6, 7, 8
OFF
19.2
21.1
7.3
8.1
452
497
HRU-402
N/A (OFF)
16.0
17.6
6.7
7.4
376
414
HRU-411
OFF
15.6
17.2
6.7
7.4
367
404
Table 19.
Power Parameters—Single Doubler (HDU-409 List 2)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
18.8
20.7
7.0
7.7
442
486
HRU-412 List 1, 2, 3, 4
OFF
18.0
19.8
7.1
7.8
424
466
HRU-412 List 6, 7, 8
ON
18.4
20.2
6.9
7.6
433
476
HRU-412 List 6, 7, 8
OFF
15.7
17.3
6.8
7.4
370
407
HRU-402
N/A (OFF)
12.5
13.8
5.9
6.5
294
323
HRU-411
OFF
12.0
13.2
5.8
6.4
283
311