Appendix A - Specifications
150-231-184-05, Revision 05
52
October 25, 1999
HLU-231 List 8D
through
show power parameters for two doubler, line-powered circuits on 9 kft, 26 AWG loops.
shows power parameters for three doubler, line-powered circuits or four doubler, locally powered
circuits on 9 kft, 26 AWG loops.
Table 20.
Power Parameters—Two Doublers (HDU-451 List 3, 4, 3B or 4B)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-402
N/A (OFF)
28.3
31.1
8.3
9.1
665
732
HRU-411
OFF
28.1
30.9
8.2
9.0
661
727
Table 21.
Power Parameters—Two Doublers (HDU-439 or HDU-437 Lists 1 and 1B)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
OFF
30.3
33.3
8.0
8.8
713
784
HRU-412 List 6, 7, 8
OFF
28.1
30.9
7.7
8.5
660
726
HRU-402
N/A (OFF)
24.8
27.3
7.2
7.9
584
642
HRU-411
OFF
27.7
30.5
7.5
8.3
652
717
Table 22.
Power Parameters—Two Doublers (HDU-409 List 2)
HRU Model No.
HRU CPE
Power
42.5 V Power Consumption
(Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3,4
ON
24.4
26.8
7.2
7.9
575
633
HRU-412 List 1, 2, 3,4
OFF
22.1
24.3
6.8
7.5
520
572
HRU-412 List 6, 7, 8
ON
25.9
28.5
7.4
8.1
609
670
HRU-412 List 6, 7, 8
OFF
20.2
22.2
6.4
7.0
476
524
HRU-402
N/A (OFF)
17.4
19.1
7.1
7.8
410
451
HRU-411
OFF
16.5
18.2
6.0
6.6
389
428
Table 23.
Power Parameters—Three and Four Doublers (HDU-409 List 2)
HRU Model No.
HRU CPE
Power
42.5 V Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 V Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-402, 3-doubler,
line-powered
N/A (OFF)
22.9
25.2
8.1
8.9
539
593
HRU-402, 4-doubler,
locally powered
N/A (OFF)
23.7
26.1
8.0
8.8
557
613