![PairGain HiGain Line Unit HLU-388 Скачать руководство пользователя страница 54](http://html2.mh-extra.com/html/pairgain/higain-line-unit-hlu-388/higain-line-unit-hlu-388_manual_3274143054.webp)
Loopback Operation
150-388-125-01, Revision 01
44
September 15, 1998
HLU-388 List 2E
Information specific to HiGain doublers is shown in bold in
.
Table 13.
Addressable 1, 2, 5 (A1LB, A2LB, A5LB) Repeater Loopback Commands
Name
Description
Code
*
*
The left most bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
Bit Error Ratio
(BER) on the facility. The IOR POWER DOWN code must remain present for the duration of the power down mode. When
this code is removed, the HiGain system returns to its normal unlooped and unarmed state. Note that the entire arming and
loopback sequence can be initiated at the remote HRU location.
ARMING or NI LPBK (in-band)
Arming code
11000 11000 ...
ARMING or NI LPBK (ESF Data Link)
Arming code
1111(F)
†
1111(F)0100(4)1000(8)
† This is the HEX number for the 4-bit group.
IR LPDN or DISARM (in-band)
Disarming code
11100 11100 ...
DISARM (ESF Data Link)
Disarming code
1111(F)1111(F)0010(2)0100(4)
IOR LPBK
(NLOC and CREM 231 errors)
HLU Loopup
1101(D)0011(3)1101(D)0011(3)
ILR-1 LPBK
(NDU1 and CDU1 10 bit errors)
DOUBLER-1 Loop up
1100(C)0111(7)0100(4)0001(1)
LR-20 LPBK
(NDU2 and CDU2 200 bit errors)
DOUBLER-2 Loop up
1100(C)0111(7)0101(5)0100(4)
ILR-2 LPBK
(NREM and CLOC 20 bit errors)
HRU Loop up
1100(C)0111(7)0100(4)0010(2)
IR LPDN
Loopdown (HLU or HRU)
1001(9)0011(3)1001(9)0011(3)
IR QUERY LPBK
Query loopback
1101(D)0101(5)1101(D)0101(5)
IR ALTERNATE QUERY LPBK
Alternate Query loopback
1101(D)0101(5)1110(E)1010(A)
TIME-OUT OVERRIDE
Loopback Time-out Override
1101(D)0101(5)1101(D)0110(6)
FAR END NI ACTIVATE
Unblock AIS and pass 2-in-5
1100(C)0101(5)0101(5)0100(4)
IOR POWER DOWN (HLU)
Removes HDSL line power
0110(6)0111(7)0110(6)0111(7)