![PairGain HiGain Line Unit HLU-388 Скачать руководство пользователя страница 35](http://html2.mh-extra.com/html/pairgain/higain-line-unit-hlu-388/higain-line-unit-hlu-388_manual_3274143035.webp)
150-388-125-01, Revision 01
Maintenance
HLU-388 List 2E
September 15, 1998
25
L
OOPBACK
M
ENU
The Loopback Menu permits you to issue loopbacks to the HiGain system. There are three possible Loopback
Menus:
•
Loopback Menu: No doubler
•
Loopback Menu: One doubler
•
Loopback Menu: Two doublers
In all instances, press
from the Maintenance Terminal Main Menu to display the Loopback Menu.
shows an example of a Loopback Menu when no doublers are present;
shows an example when one
doubler is present.
DSO Blocking
DS0
BLK
The DS0 blocking option can only be set via the RS-232 Craft port with a
terminal. The four-character line unit front panel only displays the status of the
blocking option. BLK indicates at least one channel is blocked.
NONE*
Indicates no channels are blocked.
Margin Alarm
Threshold
MARG
0 to 15 dB
The Margin Alarm Threshold can only be set via the RS-232 Craft port with a
terminal. It determines the minimum allowable margin below which a system
alarm can occur. Zero disables the alarm.
4dB*
Default value
*Indicates factory default settings.
Table 9.
HLU-388 System Settings Menu Options (Cont.)
System Settings
Menu Options
Front Panel
Display
Code
Selection
Description
'