TABLE 4. HLU-619 STATUS MENU MESSAGES (CONTINUED)
M
ESSAGE
F
ULL
N
AME
D
ESCRIPTION
CLOC
Customer Local Loopback
The loopback at HRU-612 (local) toward CI (see Figure 5)
initiated from CPE (customer) by either the ILR number 2 code,
the HLU-619 front panel Manual Loopback push buttons, or the
maintenance terminal.
CREM
Customer Remote
Loopback
The loopback at HLU-619 (remote) toward customer (see Figure
5) initiated from CPE (customer) by either the IOR code, the HLU-
619 front panel Manual Loopback push buttons, or the
maintenance terminal.
ARM
Armed
The HiGain-2 system detected the IR loopback (2 in 5) arming
code.
TLOS
Transmit Loss of Signal
(Loopback)
HRU-612 is in a logic loopback state, caused by a loss of its DS1
input from the CI when ENAbled at the HRU-612, via its TLOS
switch option.
ACO
Alarm Cutoff
The alarm output on pin H has been turned off. This state is
created by pressing the SEL button on the front panel when an
alarm has occured and persists.