background image

Section 150-619-100

Revision 01

Page 17

TABLE 3.  HLU-619 FOUR-CHARACTER FRONT PANEL MESSAGES (CONTINUED)

M

ESSAGE

F

ULL 

N

AME

D

ESCRIPTION

PWR FEED SHRT

Power Feed Short

Indicates a short between the VHDSL conductors.  This same

message can occur with an HRU, which is drawing the correct
amount of power over good cable pairs, but cannot communicate
with the HLU.

PWR FEED OPEN Power Feed Open

Indicates an open circuit in the T and R of either VHDSL pair.

PWR FEED OFF

Power Feed Off

VHDSL span power has been turned off by setting the PWFD option

to DIS.

BAD RT?

No response from
HRU

The HLU does not receive any response from the HRU.  The HRU’s
integrity is questionable.

VER XXXX

HLU software Version
number

Displayed during the System Settings review mode.  Press the Mode
button for 3 seconds.

LIST XXXX

HLU’s List number

Displayed during System Settings review mode defined above.

FRM

Frame:  SF, ESF,
UNFR, None

Defines the type of frame pattern being received from the DSX-1.
Displayed during System Settings review mode defined above.

CODE

Line Code:  AMI,
B8ZS

The line code that the HLU-619 is receiving at its DSX-1 interface, if
the DS1 option is set to Auto.  Otherwise, it mimics either of the
other two DS1 line code settings, AMI or B8ZS.  Displayed during
System Settings review mode defined above.

LOSW

Loss of Sync Word

Indicates that the VHDSL loop has lost sync.  Causes a minor alarm.

LLOS

Local Loss of Signal

Indicates that no signal is detected at the DSX-1 input to the HLU.

Causes a minor alarm.

RLOS

Remote Loss of
Signal

Indicates that no signal is detected at the DS1 input to the HRU.
Causes a minor alarm.

DS1

DS1 BPV Errors

Indicates that the number of BPVs at the HLU or HRU T1 inputs
have exceeded the 24-hour ES threshold.  Causes a minor alarm.

DS0

DS0 Blocked
Channels

Indicates status of DS0 blocked channels.  “None” indicates no
channels are blocked.  BLK indicates some channels are blocked.

MAL

Margin Alarm Loop

The margin on the VHDSL loop has dropped below the threshold (0
to 15 dB) set by the user.

MNGD

Managed

The HLU-619 is under control of the HMU-619 network management
unit.  In this state, the RS-232 maintenance port on the HLU-619
front panel is inoperative.

Содержание HIGAIN-2 HLU-619

Страница 1: ...THE FRONT PANEL 10 8 2 USING AN RS 232 TERMINAL 11 9 LOOPBACK OPERATION 12 10 HLU 619 GNLB TEST PROCEDURE 20 11 HLU 619 A1LB TEST PROCEDURE 20 12 HLU 619 A2LB TEST PROCEDURE 22 13 HLU 619 A3LB TEST PR...

Страница 2: ...slot 19 inch shelf PairGain HHS 319 3 slot 19 inch horizontal shelf PairGain HMS 317 28 slot 23 inch shelf PairGain HMS 308 8 slot remote enclosure 1 03 The Charles Ind 343 00 and 340 00 shelves do n...

Страница 3: ...ber optic systems can be installed at a leisurely pace and cut over from HiGain 2 when it is convenient The installed HiGain 2 system can then be easily removed and utilized elsewhere 3 SPECIFICATIONS...

Страница 4: ...y the transceiver and then passed on to the HLU 619 demultiplexer module The demultiplexer provides frame synchronization for the VHDSL channel The demultiplexer and VHDSL transceiver work under contr...

Страница 5: ...rcuits The line power supply converts the 48 Vdc battery to a 170 Vdc feed that provides loop power feed on the cable pair to the HRU 612 The line power supply can be turned on or off by the microproc...

Страница 6: ...helves are partitioned into two equal halves Each half should be fused at 10 A for a total of 20 A per shelf A fully loaded shelf draws 10 5 A worst case This is within the 20 A fuse limit 4 3 USING T...

Страница 7: ...us LED still flashes red and the ALRM message is still displayed Figure 3 DB 9 RS 232 I O Pin Outs A standard RS 232 DB 9 female connector on the front panel provides access to the menu interface feat...

Страница 8: ...ons should be set to the largest distance range value that does not exceed the distance from the DSX 1 to the shelf 7 04 The transmit and receive DSX 1 ports have splitting access and bridging miniatu...

Страница 9: ...150 619 100 Revision 01 Page 9 Figure 5 HLU 619 Loopback Configurations The most important of the HiGain 2 family of loopback options is the Smart Jack loopback which emulates the functions of a stand...

Страница 10: ...by pressing the SEL button for six seconds until the message DFLT NO appears 1 To set the default values press the SEL button while the DFLT NO message is displayed DFLT YES appears indicating the fa...

Страница 11: ...rgin threshold turns the margin alarm off 8 25 The other RS 232 terminal system settings are set in a similar manner Simply enter the key represented by the letter in parentheses of the parameter to b...

Страница 12: ...pecial Loopback SPLB functions A2LB and A5LB are patterned after the Teltrend addressable T1 repeater loopbacks A3LB and A4LB are patterned after the Wescom addressable T1 repeater loopbacks All four...

Страница 13: ...equence listed This interactive button procedure permits any of the four HiGain 2 loopbacks to be executed The next loopback option can be presented by pressing the Mode push button however the previo...

Страница 14: ...Disables powering to the HRU 612 ENA Enables powering to the HRU 612 ZBTS ON Tells the HiGain 2 system that the ESF frame is operating in its Zero Byte Time Slot Interface ZBTSI mode OFF Tells the HiG...

Страница 15: ...e HiGain 2 system to function as a transparent bit pipe HAIS DIS Causes the HiGain 2 system to transmit the AIS signal at both the HLU 619 and HRU 612 T1 output ports when the VHDSL loop is not in syn...

Страница 16: ...t HLU DSX 1 input LBPV Local Bipolar Violation A bipolar violation has been received at the DSX 1 input to the HLU 619 SIG Signal The HLU and HRU transceivers are trying to establish contact with each...

Страница 17: ...stem Settings review mode defined above CODE Line Code AMI B8ZS The line code that the HLU 619 is receiving at its DSX 1 interface if the DS1 option is set to Auto Otherwise it mimics either of the ot...

Страница 18: ...below the threshold 0 to 15 dB set by the user Setting the threshold to 0 inhibits the margin alarm ACO Alarm CutOff A minor alarm occurred and was retired to an ACO condition after pressing the SEL...

Страница 19: ...19 remote toward customer see Figure 5 initiated from CPE customer by either the IOR code the HLU 619 front panel Manual Loopback push buttons or the maintenance terminal ARM Armed The HiGain 2 system...

Страница 20: ...if the HRU 612 is in loopback Also verify if possible that the Loopback LED of the HRU 612 is flashing indicating that the HRU 612 is armed or that the Loopback LED lights steadily indicating that th...

Страница 21: ...1 0101 1101 0101 D5D5 IR ALTERNATE QUERY LPBK Alternate Query Loopback 1101 0101 1110 1010 D5EA TIME OUT OVERRIDE Loopback Time out Override 1101 0101 1101 0110 D5D6 FAR END NI ACTIVATE Unblock AIS an...

Страница 22: ...looped data Note This error pattern repeats every 20 seconds as long as the IOR loopback pattern is being sent This same 20 second repeat scenario also applies to the Time out Override and Query comma...

Страница 23: ...1 0110 D5D6 FAR END NI ACTIVATE Unblock AIS and pass 2 in 5 1100 0101 0101 0100 C554 IOR POWER DOWN HLU Removes VHDSL line power 0110 0111 0110 0111 6767 Note The left most bit arrives first in all se...

Страница 24: ...all the HiGain 2 loopbacks see Figure 5 All code sequences must be present for at least five seconds 2 All of the above loopbacks can also be initiated from the front panel of the HLU 619 with the Mod...

Страница 25: ...s required to execute all the HiGain 2 system loopbacks see Figure 5 All code sequences must be present for at least five seconds 3 All of the above loopbacks can also be initiated from the front pane...

Страница 26: ...was sent followed by Normal looped data Note This error pattern repeats every 20 seconds as long as the IOR loopback pattern is being sent This same 20 second repeat scenario also applies to the Time...

Страница 27: ...pback Time out Override 1101 0101 1101 0110 D5D6 IOR POWER DOWN HLU Removes VHDSL line power 0110 0111 0110 0111 6767 Note The left most bit arrives first in all sequences The detection algorithm func...

Страница 28: ...n for repair Any modifications of the unit by anyone other than an authorized PairGain representative voids the warranty 17 03 If a unit needs repair call PairGain for a Return Material Authorization...

Страница 29: ...indicate out of tolerance components or excessive temperature drift in critical components HDSL 24 Hour ES Errored Seconds The number of 1 second intervals that contained at least 1 CRC error This val...

Страница 30: ...he keyboard to return to the Main menu 20 04 System Settings Screen Viewing system settings allows you to specify any special settings for the HLU 619 For more information about these settings see sec...

Страница 31: ...istory Screen Viewing the Alarm History allows you to see information about alarms and their statue since the last time the information was cleared To use the Alarm History Screen 1 Go to the Main men...

Страница 32: ...Section 150 619 100 Revision 01 Page 32 Figure 6 HLU 619 Main Menu Figure 7 HLU 619 Status Display...

Страница 33: ...Section 150 619 100 Revision 01 Page 33 Figure 8 HLU 619 Set Clock Menu Figure 9 HLU 619 System Settings Menu...

Страница 34: ...Section 150 619 100 Revision 01 Page 34 Figure 10 HLU 619 Performance Data Screen Figure 11 HLU 619 7 Day Performance History Screen...

Страница 35: ...619 100 Revision 01 Page 35 Figure 12 HLU 619 Alarm History Screen Copyright 1996 PairGain Technologies Inc PairGain is a registered trademark CopperOptics and HiGain 2 are trademarks of PairGain Tech...

Отзывы: