150-402-102-01, Revision 01
Using the Maintenance Terminal
HRU-402 List 2
July 27, 1998
41
The IDs can only be set at the HLU. They are limited to 24 alphanumeric
characters and, like the system settings, are stored in Non-volatile Random
Access Memory (NVRAM), meaning the data remains even when power is
lost or turned off.
All six possible unit modules are always listed. Those that have not been
detected and are not present in the circuit are labeled Not Available (NA). All
detected modules are fully identified. Whenever the line unit loses sync with
Span 1, the product types are replaced by the NA label until sync is
reestablished and each module can in turn be reidentified.
1
From the Remote Terminal Main Menu screen, type
to display the
System Inventory screen:
Figure 23.
Inventory Screen
2
Type
through
to change a circuit ID.
3
Type
to exit and return to the previous menu.
SYSTEM INVENTORY
TIME: 18:16:37
DATE: 04/09/98
A. Circuit ID#:
UNIT
PRODUCT
UNIT ID
HLU
HLU-231
L8 V6.0
Not Required
B.
HRU
HRU-402
L2 V1.0
Customer Plug
C.
DB1
N/A
D.
DB2
N/A
F.
DB3
N/A
G.
DB4
N/A
Enter the item letter to change the ID, or (E)xit