150-402-102-01, Revision 01
Using the Maintenance Terminal
HRU-402 List 2
July 27, 1998
19
This screen can be identified by the heading, HiGain HLU-231 Remote
Terminal Main Menu. This is the remote unit you will be connected to.
3
At this point, you may choose to terminate the remote session by pressing
under the remote logoff option (
). Terminating the remote
session allows other units in the circuit, such as doublers, or the HLU
itself, to initiate a RS-232 session.
This is necessary because a HiGain circuit can only support one RS-232
session at a time. An active session at any module prohibits active
sessions at all other circuit modules.
Figure 7.
Local Login Main Menu Screen
The HRU-402 List 2 automatically performs a remote logoff if
no activity at the keyboard is detected after 5 minutes. This
prevents remote sessions that were not properly terminated
from blocking access to the Craft port at other locations.
,
HI-GAIN HRU-402 MAINTENANCE TERMINAL MAIN MENU (ver x)
A. VIEW SPAN STATUS
B. SET CLOCK
C. SYSTEM SETTINGS
D. VIEW PERFORMANCE DATA
E. VIEW PERFORMANCE HISTORY
G. VIEW ALARM HISTORY