PairGain 150-1504-14 Скачать руководство пользователя страница 17

Revision 01

Section 350-

431

-

114

-01

HLU-

431

 List 

1D

Page 15

1=xx or 2=yy

HDSL Loop Margins

Indicates the power of the received HDSL signal 
on each Loop relative to noise.  Any value of ‘06’ 
or greater is adequate for reliable system 
operation.

PWR FEED 
SHRT

Power Feed Short

Indicates a short between the 2 HDSL pairs in 
span 1.  This same message can occur with an 
HRU that is drawing the correct amount of 
power over good cable pairs but cannot 
communicate with the HLU.

PWR FEED 
OPEN

Power Feed Open

Indicates an open circuit in the T&R of either 
HDSL pair in span 1.

PWR FEED 
OFF

Power Feed Off

HDSL span power has been turned off by setting 
the PSFD option to DIS.

BAD RT?

No response from HRU The HLU does not receive any response from the 

HRU.  Thus, the HRU’s integrity is questionable.

VER

HLU Software 
Version #

Displays during the System Settings review 
mode. Depress the 

MODE

 button for 3 seconds 

to view the saoftware version.

LIST 0xL

HLU’s List #

Displayed during System Settings review mode 
defined above.

FRM

Frame: SF, ESF, UNFR, 
NONE

Defines the type of frame pattern being received 
from the DSX-1. Displayed during System 
Settings mode defined above.

CODE

Line Code:  AMI, B8ZS

This is the line code that 

HLU-

431

 List 

D

 is 

receiving at its DSX-1 interface.  Displayed 
during System Setting review mode.

DS0

DS0 Blocked Channels

Indicates status of DS0 blocked channels.  
NONE indicates no channels are blocked.  BLK 
indicates some channels are blocked. 

MNGD

Managed

The HLU-431 List 2D is under control of the 
HMU network management unit.  In this state, 
the RS-232 maintenance port on the 
HLU-431’s front panel is inoperative.

Four-Character Front Panel Messages (Cont.)

Message

Full Name

Description

  These messages only apply to systems with doublers present.

Содержание 150-1504-14

Страница 1: ...QUICK INSTALLATION GUIDE PAIRGAIN TECHNOLOGIES INC SECTION 350 431 114 01 Revision history of this guide Revision 01 January 27 1998 A Initial Release Model List Part Number CLEI Code HLU 431 1D 150 1...

Страница 2: ...Messages 14 Specifications 16 Documentation 16 Technical Support 16 Bulletin Board Services 17 Copyright 1998 PairGain Technologies Inc PairGain and HiGain are registered trademarks of PairGain Techn...

Страница 3: ...nit to provide a complete HiGain High bit rate Digital Subscriber Line HDSL system This guide addresses HLU 431 List 1D operation when used with and without doublers For applications without doublers...

Страница 4: ...wn in the Card Edge Connectors on page 4 HRE 420 Single Slot HRE 422 Dual Slot HRE 427 Seven Slot HRE 450 Single Slot Outdoor HRE 454 Four Slot Outdoor Status LED States State Description Green Normal...

Страница 5: ...nstallation Upon receipt of the equipment visually inspect it for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and...

Страница 6: ...Section 350 431 114 01 Revision 01 Page 4 HLU 431 List 1D Card Edge Connectors The HLU 431 card edge connector pinouts are shown below...

Страница 7: ...ng the Line Unit To install the HLU 431 into a shelf slide the unit into the shelf card guides for the desired slot then push the unit in until it is entirely within the card guide and the retaining l...

Страница 8: ...via buttons on the front panel or through the RS 232 interface They are retained if shelf power is lost or if the HLU 431 List 1D is unplugged The System Options table on page 8 lists the system optio...

Страница 9: ...use a standard RS 232 cable to connect your system to a dumb terminal or PC running a terminal emulation program Once connected you can access the maintenance provisioning and performance screens To...

Страница 10: ...equalizer to DSX 1 for 533 655 feet ZBTS ON Tells HiGain that the ESF frame is operating in its ZBTSI mode OFF Tells HiGain that the ESF frame is operating in its normal non ZBTSI mode ESAL 17 Activat...

Страница 11: ...res the HiGain system to respond to the generic 3 4 5 6 in 7 in band loopback codes A1LB and A2LB Configures the HiGain system to respond to the Teltrend addressable repeater in band loopback codes A3...

Страница 12: ...it the AIS signal at both the HLU and HRU T1 output ports when both of the HDSL loops are not in sync LOSW 1LP Causes HiGain to transmit the AIS signal at both the HLU and HRU T1 output ports when eit...

Страница 13: ...Signal No signal at the HLU 431 List 1D local T1 interface RLOS Remote Loss of Signal No signal at the HRU remote T1 interface LOSW1 or LOSW2 Loss of Sync Word 1 or 2 HDSL loop 1 or 2 has lost sync H1...

Страница 14: ...he CBA initiated by upstream in band codes or from the maintenance terminal NLOC Network Local Loopback Loopback at HLU local toward the CBA initiated by upstream in band codes or from the maintenance...

Страница 15: ...in band codes or the maintenance terminal NDU2 Network Doubler 2 Loopback The loopback at doubler 2 toward the CBA initiated by in band codes or the maintenance terminal CDU1 Customer Doubler 1 Loopb...

Страница 16: ...2nd Doubler and HRU transceivers are trying to establish contact with each other on loops 1 or 2 of span 3 ACQ 1 or 2 Acquisition 1 or Acquisition 2 The HLU and HRU or 1st Doubler multiplexers are try...

Страница 17: ...uestionable VER HLU Software Version Displays during the System Settings review mode Depress the MODE button for 3 seconds to view the saoftware version LIST 0xL HLU s List Displayed during System Set...

Страница 18: ...y comments on any PairGain documentation send mail to technical_publications pairgain com Type the product name and the section number of the document in the subject area of the email message Technica...