Revision 01
Section 350-
431
-
114
-01
HLU-
431
List
1D
Page 9
DS0
BLK
The DS0 blocking option can only be set through the RS-232
maintenance port with a terminal. The 4-character HLU-319 List
2D front panel LED readout only displays the BLK indicates at least
one channel is blocked.
NONE*
No channels are blocked.
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after
initiation.
60*
Sets automatic cancellation of all loopbacks to 60 minutes after
initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after
initiation.
LPBK
DIS
Configures the HLU-200 to ignore the 2 in 5 Smart-Jack loopback
command.
ENA*
Enables the HLU-200 to respond to the 2 in 5 Smart-Jack loopback
command.
SPLB
GNLB*
Configures the HiGain system to respond to the generic
(3/4/5/6 in 7) in-band loopback codes.
A1LB and
A2LB
Configures the HiGain system to respond to the Teltrend
addressable repeater in-band loopback codes.
A3LB
Configures the HiGain system to respond to the Wescom
addressable repeater in-band loopback codes.
A4LB
Configures the HiGain system to respond to the Wescom Mod 1
addressable repeater in-band loopback codes.
A5LB
Configures the HiGain system to respond to the Teltrend Mod 1
addressable repeater in-band loopback codes.
PWRF
DIS
Disables powering to the HRU and/or doubler over the HDSL pairs.
ENA*
Enables powering to the HRU and/or doubler over the HDSL pairs.
DS1
B8ZS
Places both the HLU and HRU into their B8ZS modes.
AMI*
Places both the HLU and HRU into their AMI modes.
AUTO
The HLU and HRU independently monitor their incoming T1 bit
streams for the B8ZS pattern. If either unit detects this pattern, it
enters its B8ZS mode.
HLU-
431
List
1D
System Options (Cont.)
Mode
Selection
Description