Section 350-
431
-
114
-01
Revision 01
Page 8
HLU-
431
List
1D
3
On each screen, enter the key represented by the letter in parenthesis for
the parameter to be changed.
•
Each entry of this letter scrolls the parameter to its next value.
•
After all selections have been made, press
to exit and
to con-
firm the changes. This activates the new choices and returns control
to the Main Menu screen.
The following three user options cannot be set from the front panel buttons:
Circuit ID, DS0 Blocking, and Margin Alarm Threshold.
System Options Settings
HLU-
431
List
1D
System Options
Mode
Selection
Description
EQL
†
0*
Sets the equalizer to DSX-1 for 0 - 133 feet.
133
Sets the equalizer to DSX-1 for 133 - 266 feet.
266
Sets the equalizer to DSX-1 for 266 - 399 feet.
399
Sets the equalizer to DSX-1 for 399 - 533 feet.
533
Sets the equalizer to DSX-1 for 533 - 655 feet.
ZBTS
ON
Tells HiGain that the ESF frame is operating in its ZBTSI mode.
OFF*
Tells HiGain that the ESF frame is operating in its normal
non-ZBTSI mode.
ESAL
17
Activates the alarm input signal to the LITESPAN microprocessor
and flashes the red STATUS LED when 17 Errored Seconds (ES)
(17 HDSL CRC errors on either HDSL loop or a total of 17 BPVs and
FERR) occur within a 24-hour period.
170
Activates the alarm input signal to the LITESPAN microprocessor
and flashes the red STATUS LED when 170 ES (170 HDSL CRC
errors on either HDSL loop or a total of 170 BPVs and FERR) occur
within a 24-hour period.
NONE*
Prevents generation of an alarm due to excessive Errored Seconds.
ALM
DIS*
Disables assertion of the Alarm input signal to the LITESPAN
processor from the HLU processor. Note the HDSL LED still
flashes Red for an alarm condition even when the ALM DIS option
is chosen.
ENA
Enables assertion of the Alarm input signal to the LITESPAN
processor from the HLU processor.
E
C
Содержание 150-1504-14
Страница 20: ......