150-388-105-05, Revision 05
Overview
HLU-388 List 5
March 25, 2000
1
O
VERVIEW
The PairGain
®
HiGain
®
Line Unit HLU-388 List 5 is the Central Office (CO) side of a repeaterless
T1 transmission system. When used in conjunction with a HiGain Remote Unit (HRU), the system provides
1.544 Mbps transmission on two unconditioned copper pairs over the full Carrier Service Area (CSA) range. The
CSA includes loops up to 12,000 feet of 24 American Wire Guage (AWG) wire or 9,000 feet of 26 AWG wire,
including bridged taps. This line unit can be used with HiGain Doubler Units (HDUs) to extend reach.
F
EATURES
•
Five-span range with four doublers (60 kft, 24 AWG)
•
Four line-powered spans (three doublers and one remote)
•
Reduced power consumption
•
Ultra-low wander (Stratum 1 compliant)
•
Low line-power option setting (-140 Vdc) for circuits with a single doubler
•
Selectable Power Feed (PWRF) modes: AUTO, HIGH, and LOW
•
Grounded loop detection on High-bit-rate Digital Subscriber Line (HDSL)
•
Bipolar Violation Transparency (BPVT) options
•
Bit Error Rate (BER) alarm options
•
HRU loopback screen
•
Inventory Screen (displays Circuit ID and unit ID numbers)
•
Loss of Signal/Alarm Indicator Signal (LOS/AIS) payload alarm option
•
Remote Loss of Signal (RLOS) disable alarm option
•
Supports HRU-411 in Personal Communications System (PCS) applications
•
Improved performance for AUTO DS1 line code mode
•
Default setting screen option
•
Payload (PL) or HiGain (HG) loopback source identification
•
Troubleshooting screen
•
Selectable DS1 pre-equalizer
•
Front-panel features:
–
Four-character status display
–
Status Light Emitting Diode (LED)
–
RS-232 craft port for connection to a maintenance ASCII terminal or terminal emulation program
•
Compatible with Double Dual Module Plus (DDM+) high-density shelves
•
Selectable loopback activation codes
•
Network Management and Administration (NMA) interface
•
Lightning and power cross protection on HDSL interfaces
•
Full duplex 2B1Q HDSL transmission on two pairs at 784 kbps
•
Margin threshold alarm