150-388-105-05, Revision 05
Front Panel
HLU-388 List 5
March 25, 2000
7
BAD RT?
No response from HRU
The HLU does not receive any response from the HRU. Thus, the
integrity of the HRU or the two HDSL loops (they may be open) is
questionable.
CODE xxxx
Line Code: AMI, B8ZS, AUTO
The line code that HLU-388 List 5 is receiving at its DSX-1 interface,
if the DS1 option is set to Auto. Otherwise, it mimics one of the other
two DS1 line code settings: Alternate Mark Inversion (AMI) or
Bipolar with 8-zero Substitution (B8ZS). Displayed during System
Settings review mode.
DS0
DS0 Blocked Channels
Indicates status of DS0 blocked channels. NONE indicates no
channels are blocked. BLK indicates some channels are blocked.
FERR
Framing Bit Error
Framing bit error occurred at HLU T1 input.
FRM
Frame: SF, ESF, UNFR, NONE
Defines the type of frame pattern being received from the DSX-1:
SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR),
or NONE. Displayed during System Settings review mode.
H1ES or H2ES
HDSL CRC Error Channel 1 or
Channel 2
HDSL Loop 1 or Loop 2 CRC error.
nHDU
Number of Doublers
This message indicates the number (n) of doublers in the circuit.
INSL, then xxdB
Insertion Loss (Maximum)
The Maximum Insertion Loss message (INSL) appears followed by
xxDB, where xx is the maximum insertion in dB of all spans and
loops.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the T1 input to the HLU-388.
LIST xxxx
HLU-388 List Number
The software list number appears during the System Settings review
mode. Press the MODE button for 3 seconds to display the list
number.
MNGD
Managed
The HLU is under control of the HMU-319 network management
unit. In this state, the front-panel craft port is disabled.
PWRF GND
Power Feed Ground
One of the HDSL loops has been grounded.
PWRF ON
Power Feed On
Indicates that the HDSL loops are not grounded or shorted.
PWRF OFF
Power Feed Off
HDSL span power has been turned off by setting the PWFD option
to DIS, or HDSL span power has been turned off by use of the
A1LB/A2LB/A5LB Intelligent Office Repeater (IOR) Power Down
code.
PWRF SHRT
Power Feed Short
Indicates a short between the two HDSL pairs. This same message
can occur with an HRU that is drawing the correct amount of power
over good cable pairs but cannot communicate with the HLU.
SELF TEST
Self Test
The HLU is in a self-test mode. This occurs every power On/Off
cycle.
SIG1 or SIG 2
Signal 1 or Signal 2
The transceivers of the HLU and the HRU, or first doubler, are trying
to establish contact with each other on Loop 1 or Loop 2 of Span 1.
SnL1 or SnL2
Signal n Loop 1 or Loop 2
The transceivers of the first doubler and either the HRU or second
doubler are trying to establish contact with each other on Loop 1 or
Loop 2 of Span n.
VER xxxx
HLU-388 Version Number
The software version number (xxxx) appears during the System
Settings review mode. Press the MODE button for 3 seconds to
display the software version.
Table 3.
Front Panel Display Messages (Cont.)
Message
Full Name
Description