background image

5

Jet Swim 1200

MA30-01E

ENGLISH

W2 U2 V2

U1 V1 W1

W2 U2 V2

U1 V1 W1

Pressure

switch

Connector

Motor circuit 

breaker

PE

Micro

switch

Connector

Motor circuit 

breaker

PE

Pressure

switch

Product Description

Jet Swim is an apparatus used for training, exercise and recreation. It features an adjustable jet stream for personal

customisation of the water flow and air admixture.

Technical Data

Motor

2.2 kW

Volage

230/400V 50Hz 3N~

265/460V 60Hz 3N~

Current

7.6 / 4.4 A

7.4 / 4.3 A

Pump capacity

900 l/min

Enclosed protection class

Pump X4, Control box IP45

General information

Jet Swim 1200 consists of four parts:  

Base kit

  

1301200 

  

 

   

Assembly kit

   1301210 Liner, 1301220 Concrete/liner or 1301230 Concrete 

  

 

   

Pump kit

  

1301280-01 (50Hz), 1301280HZ-01 (60Hz) 

  

 

   

Control box

   1301290 400V, 130129NO 230V Norway only

The pump section is installed on a stable surface in a dry area. Make sure that the area is well ventilated and is equipped with

a drain in order to prevent flooding.

All installation of stainless steel parts shall be done using tools solely intended for such material in order to maintain its

corrosion-resistance.

Recommended Values with Regard to Water Quality

Free chlorine:

0.5–1.5 mg/litre (ppm)

pH-value:

7.2–7.6

Combined chlorine:

0–0.5 mg/litre (ppm)

Alkalinity:

60–120 mg/litre (ppm)

Totalt chlorine:

0.5–2.0 mg/litre (ppm)

Calcium hardness:

100–300 mg/litre (ppm)

Chloride (salt) content:

max 250 mg/litre

Safety

The jet stream is powerful, which is why one should not be closer than 0.5 m from the stream outlet for a protracted period.

People with long hair should pay careful attention so that their hair does not get stuck in the inlets (the perforated openings in

the stainless steel front).

Small children should not be in the pool without supervision, especially not when the Jet Swim device is in operation.

Always inform all the other bathers in the pool before starting the Jet Swim.

Electrical Installation

All electrical connections shall be made by an authorised electrician.

The device shall be fitted with a residual current device.

The pump motor is connected via the control box for Jet Swim 1200, see the circuit diagram. 

Check the rating plate on the pump motor for the correct connection on the closing link.

Make sure that the pump motor has been connected in the correct direction of rotation (see the rotation direction arrows on the

pump motor). The wrong direction can damage the pump. N.B.! The pump must never be started without being filled with water.

Make sure that the motor protection in the control box is set according to the rated current of the pump motor; see the rating plate.

Circuit

Diagram 

Содержание Jet Swim 1200

Страница 1: ...Pahlén AB Box 728 SE 194 27 Upplands Väsby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com Manual User manual Инструкция Gebrauchsanleitung MA30 01 rev 1 Swedish design and manufacture since 1967 ...

Страница 2: ...l Register Содержание Inhaltsverzeichnis Dimensioner Dimensions Размеры Dimensionen Mått inom parantes avser art nr 1301210 för pool med liner och stomme av trä plåt eller plast Dimensions put in brackets refer to item no 1301210 for liner pools with walls made of wood sheet or plastic Размеры в скобках действительны для арт 1301210 для плёночных бассейнов Grössenangaben in Klammern beziehen sich ...

Страница 3: ... 0 0 5 mg liter ppm Alkalinitet 60 120 mg liter ppm Totalt klor 0 5 2 0 mg liter ppm Kalciumhårdhet 100 300 mg liter ppm Klorid salt halt max 250 mg liter Säkerhet Jetstrålen är stark vistas därför inte närmare än 0 5 m från strålens utlopp Personer med långt hår skall vara extra uppmärksamma så att håret ej fastnar i insuget de utstansade öppningarna på den rostfria fronten Små barn bör ej vistas...

Страница 4: ...samt ingjutningsrören för luftinblandning och startslang skyddsrör före gjutning Gängorna tätas med gängtejp 3 Efter gjutningen och eventuell kakelsättning monteras den rostfria fronten 4 Anslut slangen för luftinblandning och drag åt slangklammern Fäst sedan mynningen på slangen 100 mm ovanför vattenytan bakom poolväggen 5 Anslut startslangen till pumpens kontaktorskåp OBS Startslangen skall lägg...

Страница 5: ...2 7 6 Combined chlorine 0 0 5 mg litre ppm Alkalinity 60 120 mg litre ppm Totalt chlorine 0 5 2 0 mg litre ppm Calcium hardness 100 300 mg litre ppm Chloride salt content max 250 mg litre Safety The jet stream is powerful which is why one should not be closer than 0 5 m from the stream outlet for a protracted period People with long hair should pay careful attention so that their hair does not get...

Страница 6: ...Jet Swim housing and install the non leak flanges for the suction and pressure connections and the non leak flanges for the air injection and start hose protective hose before casting The threads are to be sealed with thread tape 3 Install the stainless steel front plate after the casting and any tiling 4 Connect the hose for the air admixture and tighten the hose clamp Fasten the end of the hose ...

Страница 7: ...льно для данного материала Рекомендуемые параметры качества для воды Свободный хлор 0 5 1 5 мг л ppm Значение pH 7 2 7 6 Связанный хлор 0 0 5 мг л ppm Щелочность 60 120 мг л ppm Общее содержание хлора 0 5 2 0 мг л ppm Кальциевая жесткость 100 300 мг л ppm Содержание хлоридов солей макс 250 мг л ppm Безопасность Струя противотока обладает большой мощностью поэтому нельзя находиться на расстоянии бл...

Страница 8: ...лжен находиться на 230 мм ниже уровня воды 2 Подсоедините стартовый шланг к корпусу противотока и вмонтируйте нагнетающий и всасывающеий патрубки а так же трубу для смешивания воздуха и стартовый шланг с защитной трубкой до заливки Резьбовые соединения уплотните изолентой 3 После заливки и возможной облицовки монтируется панель противотока 4 Подсоединитe шланг для смешивания воздуха и затяните шла...

Страница 9: ......

Страница 10: ...2 1 8 Ø Draw no R10586 D 4 5 ...

Страница 11: ...9 236 230 mm to water level Water Level 230 mm till vattenytan 230 mm to the water surface 230 мм поверхность воды 230 mm zu die Wasseroberfläche Vattenyta Water surface Поверхность воды Wasseroberfläche ...

Страница 12: ......

Страница 13: ...mg liter ppm Alkalität 60 120 mg liter ppm Chlor gesamt 0 5 2 0 mg liter ppm Kalziumhärte 100 300 mg liter ppm Klorid salt halt höchstens 250 mg liter Sicherheit Der Jet Strahl ist stark halten Sie sich nicht für längere Zeit näher als 0 5 m vom Jet Ventil entfernt auf Menschen mit langen Haaren müssen außerdem darauf achten dass sich die Haare nicht in der Ansaugöffnung den gestanzten Löchern am ...

Страница 14: ...eren Sie vor dem Giessen die Mauerdurchführungen für die Saug und Druckverbindungen sowie die Mauerdurchführungen für die Lufteinmischung und den Startschlauch Schutzschlauch Dichten Sie die Gewinde mit Gewindeband ab 3 Nach dem Gießen und eventuellem Verfliesen montieren Sie den die Edelstahl Front 4 Schließen Sie den Luftschlauch an und ziehen Sie die Schlangklemme fest Befestigen Sie dann die Ö...

Страница 15: ...s 7 1 Gate valve 2 brass 8 1 Gate valve 2 devided brass 9 1 Clamping ring 10 1 Rubber gasket Ø258mm t 2mm 11 8 Screw MRX A4 M5x12 12 2 Screw MC6S A4 M8x16 13 2 Bushing nylon 14 1 O ring 4 10x1 60mm 15 1 Connection pin 16 2 Spring washer 17 2 1pc Hose connection air injection 1pc Protective pipe start hose 18 1 Hose for air injection 8x12mm L 0 8m 19 1 Hose clamp 8 14mm 20 1 Hose for start 2x4mm L ...

Страница 16: ...ton complete 4 1 Turning insert 5 1 Jet Swim 1200 housing 6 2 Non leak flange 2 connection L 250mm 7 1 Gate valve 2 brass 8 1 Gate valve 2 devided brass 9 1 Clamping ring 10 1 Rubber gasket Ø258mm t 2mm 11 8 Screw MRX A4 M5x12 12 2 Screw MC6S A4 M8x16 13 2 Bushing nylon 14 1 O ring 4 10x1 6mm 15 1 Connection pin 16 2 Spring washer 17 2 1pc Hose connection air injection 1pc Protective pipe start ho...

Страница 17: ...4 M6x12 3 1 Start button complete 4 1 Turning insert 5 1 Jet Swim 1200 housing 6 2 Non leak flange 2 connection L 250mm 7 1 Gate valve 2 brass 8 1 Gate valve 2 devided brass 9 10 11 12 2 Screw MC6S A4 M8x16 13 2 Bushing nylon 14 1 O ring 4 10x1 6mm 15 1 Connection pin 16 2 Spring washer 17 2 1pc Hose connection air injection 1pc Protective pipe start hose 18 1 Hose for air injection 8x12mm L 0 8m ...

Страница 18: ...skruv med sexkantshål ISO 4026 M8 x 10 1 2 3 Stoppskruv med sexkantshål ISO 4026 M8 x 10 2 2 4 Axeltätning typ CD201 1 3 Mellandel 1 4 Pumphus 2kW 1 5 Slangsockel 2tum 6 6 Tryckslang 4 7 Slangklammer 8 8 M10 x 25 Sexkantskruv 4 9 M10 mutter 4 10 M10 x 30 Sexkantskruv 4 11 O ring 1 12 Platta 1 13 M 12 kupolmutter 1 14 Pumphjul Jet 2 2kW 1 15 M6 x 10 Sexkantskruv 1 16 M6 bricka koppar 1 17 Automatik...

Страница 19: ......

Страница 20: ...äsby Sweden Email info pahlen se www pahlen com We do not accept liability for printing errors We reserve the right to make changes to specification and product range Colour deviation may occur due to restrictions in the printing process ...

Отзывы: