6
Auto-UV 75 & 130
MA60-19 E
ENGLISH
Th
is
d
oc
um
en
t a
nd
it
s
co
nt
en
ts
a
re
th
e
ex
cl
us
iv
e
pr
op
er
ty
o
f P
ah
lé
ns
a
nd
m
ay
n
ot
b
e
co
pi
ed
,
re
pr
od
uc
ed
, t
ra
ns
m
itt
ed
o
r c
om
m
un
ic
at
ed
to
a
th
ird
pa
rty
, o
r u
se
d
fo
r a
ny
p
ur
po
se
w
ith
ou
t w
rit
te
n
pe
rm
is
si
on
.
Art.no.
Rev.no.
Scale
Designed by:
Approved by:
Revised by: Date
Drawn by: Date
Drawing number
Assembly drawing no.
Surface treatment
part of ISO 2768-1
The tolerance class in accordance with this
E
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
417760
CRO 2010-12-06
TS
2012-07-08
Auto-UV 75
Auto-UV 75
M11310 3
G2" (2x)
77
2
(5
70
-
67
0)
141
145
80
18
0
10
00
67
,5
Sid 2 (2)
6(4x)
1000
570-670
141
145
G2”(2x)
Ø80
772
180
Ø6 (4x)
67
,5
Skimmer
Main drain
Light
Jet Swim
Inlet
Filter
Pump
Drain
Electric heater
Check valve
Light
Auto-UV
Product description
The Pahlén Auto-UV is designed for the disinfection of water in swimming pools.
The UV lamp generates UVC radiation, which neutralises bacteria, viruses and algae.
The Auto-UV can reduce total chlorine consumption by up to 70%, wich reduces the content of combined chlorine. This creates
a more pleasant environment for bathers, with less chlorine odour and a reduced risk of allergic reactions and red eyes.
For installations with high flows, we recommend two or more UV cleaners
connected in parallel. Bypass installations can also be used.
Technical data
Auto-UV 75W
Auto-UV 130W
Max. pressure
4 bar (0.4 MPa)
4 bar (0.4 MPa)
Max. flow
max. 250 l/min
max. 250 l/min
Lamp
75 W
130 W
Lamp operating time
9000 h
9000 h
Voltage
220-240V 1N~
220-240V 1N~
Rated current
0.5 A
0.8 A
IP
44
44
Connection
G2”
G2”
Water temperature
+5 to +45°C
+5 to +45°C
UVC-wavelength
254 nm
254 nm
UVC-output
25W
43W
Weight
5 kg
6.6 kg
Follow the instructions stated below regarding water quality:
Chlorine content:
max 3 mg/l (ppm)
pH value:
7.2 - 7.6
Alkalininty:
60-120 mg/l (ppm)
Calcium hardness:
100-300 mg/l (ppm)
General info
Please note that the UV lamp and the quartz glass are sensitive to impact. The lamp and quartz glass must never be touched
without gloves (cotton gloves supplied). NOTE: Read the entire manual before installation and commissioning.
Safety
The Auto-UV must never be started without being filled
with water. The water in the system must be flowing,
otherwise there is a risk of overheating.
Never use the Auto-UV together with bromine treatment.
A damaged unit must not be used (risk of UVC radiation leak).
The Auto-UV may only be handled by people with the necessary competence, and if there is the slightest doubt a swimmingpool
installer/technician must be contacted.
“Persons (including children) with limited physical
or mental capabilities must not use the device
without instructions on how to use it in a safe
manner,” as per IEC 60335-1.
Pipe installation
The Pahlén Auto-UV must be installed vertically,
after filters and before heaters.
There must be a free distance of 1 m above the
casing to facilitate replacement of the UV lamp.
We recommend a by-pass installation of one or
several Auto-UV’s to make service and flow
adjustment easy.
Screw the pipe connections
firmly into place and seal with
a suitable thread sealer.
Warning!
UV radiation is harmful to the eyes and the skin.
The UVC lamp must never be switched on out-
side its casing.
!