![background image](http://html1.mh-extra.com/html/pag/paglink-pl16-series/paglink-pl16-series_instructions-manual_3230957006.webp)
6
2.4
PAGlink Charging:
Up to 8 PAGlink batteries can be charged on each position. Batteries can be
in any state of charge. The most discharged batteries will be given priority.
Fully charged batteries stop accepting charge automatically and independently.
Batteries may be left on the charger when fully-charged and will be
maintained in a ready-for-use condition.
2.5
Recovery Charge Program:
A battery that will not accept charge, and is indicated as ABST on the charger
display, can be given a Recovery Charge, initiated by two presses of the front
panel button on PL16 Chargers (Models 9707 & 9707A). Normal charging will
follow after a few seconds. Recovery Charge will be applied automatically in the
case of PL16+ chargers (Models 9711 & 9711A). Additionally, all chargers will
recover automatically a Li-Ion battery where the output has been shut down.
2.6
Self Test Program:
The internal microcomputer constantly monitors the battery under charge, as
well as the operation of the charger’s own functions, which will be shut down
to a safe condition should any of the tests fail.
2.7
Mains Input:
100V to 265V AC. Frequency 50-60 Hz. Maximum consumption 220W.
2.8
Output Protection:
The charger is protected against short circuit and excess battery voltage.
2.9
AC Mains Failure Protection:
Should mains failure occur during a charging program, or whilst the charger is
connected, it will shut down to a safe condition.
2.10
User Interface:
The charge status of each PAGlink battery is indicated by its own display.
The different stages of the charging process are indicated for each channel on
the charger’s LCD screen. The charger is fully automatic in operation.
2.11
Safety:
Designed to comply with electrical safety standard BS EN 60065 and UL1564.
NOTE: UK AC power leads are fitted with a 1" fuse to BS1362 rated 5A.
2.12
European Union Directives:
Complies with the following EU Directives:
EMC Directive 2004/108/EC.
Low Voltage Directive 2014/35/EU.
2.13
Operating Temperature Range:
0ºC to +40ºC (+32ºF to +104ºF).