Pacific Proteus 210E Скачать руководство пользователя страница 7

 

 

Page 7 of 14 

 
 
 

MACHINE PREPARATION 

8) HOSE CONNECTIONS

  

Open the lid and confirm the following 
connections are secure: 

a)  The vacuum cover (2) is securely 

attached, turn clockwise to tighten. 

b)  The vacuum hose (1) is attached. 
c)  The hose cuff on the vacuum hose (on 

the back of the machine) is inserted. 

9) POWER CORD OPERATION 

The total length of cord is 65 feet. Pull the 
cord to the length needed. It should lock to 
length.  If the cord does not automatically 
lock, pull out the cord from 2.5 to 15 inches 
and then release the cord.  The cord will 
now be locked.  Plug the machine's power 
cord into a properly grounded outlet. 

 

Содержание Proteus 210E

Страница 1: ... ensure that there is no concealed freight damage If damage is discovered file a CONCEALED DAMAGE REPORT immediately with the delivering carrier The content of this manual are based on the latest product information available at the time of publication Pacific Steamex reserves the right to make changes or improvements to its machines without notice For new manuals write to Pacific 2259 S Sheridan ...

Страница 2: ...f least resistance for electric current to reduce the risk of electric shock This machine is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances 11 Avoid damage to the machine s electrical cord Always lift the machine over the co...

Страница 3: ... Indicator Water Flow Rate Indicator Brush Drive Motor Control Switch Vacuum Motor Control Switch Squeegee Lift Lever Indicator Waste Fluid Drain Indicator Maximum temperature of fluid added to Solution Tank is 50 Celsius 120 Fahrenheit Tie Down Location Indicator ...

Страница 4: ...d tie down straps c Pull the machine off the pallet 2 SQUEEGEE ASSEMBLY a Assemble the squeegee as shown in the figure to the right The squeegee lever should be in its up position b Insert the locking pin into the squeegee stud bolt to secure the squeegee in place c Push the squeegee hose over the squeegee vacuum port The hose should be located to the right of the squeegee lift cable ...

Страница 5: ...r 4 ADJUSTING SQUEEGEE INCLINATION During operation the rear squeegee blade is most efficient when bent backwards roughly 3 16ths of an inch along its entire length To increase the blade bending in the center of the squeegee tilt the squeegee body backward by turning the adjuster screw counter clockwise Conversely turn the adjuster screw clockwise to increase the bending at the outside edges of sq...

Страница 6: ...r retaining springs until locked The image at the lower right shows the direction of rotation for installing the right brush The left brush is rotated in the opposite direction 7 SOLUTION WATER Fill the solution tank with clean water at a temperature of no more than 50 C 120 F Add the proper concentration of liquid detergent by following the manufacture s instructions Excess foam in the recovery t...

Страница 7: ...1 is attached c The hose cuff on the vacuum hose on the back of the machine is inserted 9 POWER CORD OPERATION The total length of cord is 65 feet Pull the cord to the length needed It should lock to length If the cord does not automatically lock pull out the cord from 2 5 to 15 inches and then release the cord The cord will now be locked Plug the machine s power cord into a properly grounded outl...

Страница 8: ...type of floor the dirt level and the scrubbing speed 5 Release the foot pedal and lower the brush base 6 Lower the squeegee using lever 4 7 The brushes turn by pulling on levers 5 until they touch the handle grip During the first few yards of operation check that the quantity of the cleaning solution is sufficient to wet the floor and that the squeegee dries the floor surface 8 OVERFILL PROTECTION...

Страница 9: ...he squeegee is not raised during storage or transport 4 Turn off the brush switch 3 5 Turn off the vacuum motor switch 4 6 Disconnect the machine s power cord from the electrical outlet 7 Inspect the power cord and plug for nicks cuts and any other damage Report any damage to your service manger for repair 8 Clean the power cord with rag Make sure there is no water or dirt on the power cord 9 Pull...

Страница 10: ...off the vacuum cap 1 by rotating it counter clockwise 13 Remove the filter and its housing 14 Rinse the tank with clean water CLEANING THE VACUUM FILTER 15 Lift the cover 16 Take off the vacuum cap by rotating it counter clockwise 17 Remove the filter and its housing 18 Use water to clean the walls and the bottom of the filter 19 Remove the filter and its housing 20 Wash all components thoroughly ...

Страница 11: ...the squeegee blades 27 Remove the squeegee vacuum hose from its port 28 Remove the locking pin from the stud bolt 29 Remove the squeegee from its support 30 Loosen the wing nuts 1 that lock the rubber blades and take them off 31 Replace the blades 32 To reassemble the squeegee repeat the above operations in reverse BRUSH PAD DRIVER REMOVAL To remove the brushes pad drivers 33 Lift the brush base w...

Страница 12: ...queegee 37 Remove the other end of the vacuum hose from the recovery tank 38 Wash the inner part of the hose with clean water 39 Reassemble WARNING Do not wash the hose that goes from the vacuum motor to the vacuum cap SOLUTION TANK CLEANING 40 Remove the fill cap of the solution tank 41 Rinse with clear water 42 Remove the drain cap 1 and empty the solution tank WARNING Use gloves for protection ...

Страница 13: ...ery tank d Remove the entire vacuum assembly and clean it e Replace the blades if worn f Check that the vacuum motor switch is on g Check the squeegee height adjustment see MACHINE PREPARATION section 3 4 POWER CORD WILL NOT EXTEND a If the ratchet is locked please contact a service center 5 POWER CORD WILL NOT RETRACT a If the ratchet is locked please contact a service center b If the return spri...

Страница 14: ...mproper use abuse or neglect Warranty credit of return parts including motors pumps etc is subject to incoming inspection of those items To secure repair under this warranty the following procedure should be taken 1 After the expiration of the ninety 90 day travel time warranty period the customer is responsible for warranty travel payment for the inoperative machine or warranted parts must be del...