11.
11.
十.排除故障
Issue
Cause
What to do
After installation
,
the unit doesn’t
work.
1. The power source is not turned
ON.
1. Make sure the circuit breaker
and the unit’s power is ON.
2. The power line and the cable
locking connector is not connecting
properly.
2. Check the power connection
with the unit is connected properly.
3. The wires on rotary switch are
loose.
3. Make sure the wires on the
switch are connected properly.
4. The switch is defective.
4. Change the switch.
Light works
,
but
motor is not turning.
1. The motor is defective
,
possible
seized.
1. Change the motor.
2. The thermally protected system
detects if the motor is too hot to
operate and shuts the motor down.
2. The motor will function properly
after the thermally protected
system cool down.
3.
D
amaged capacitor.
3. Change the capacitor.
4. The motor wire is not connected. 4. Make sure the motor wire is
plugged into the molex connector.
The unit is vibrating.
1. The motor is not secure in place.
1. Tighten the motor in place.
2.
D
amaged blower wheel.
2. Change the blower wheel.
3. The hood is not secured in place. 3. Check the installation of the
hood.
The motor is
working
,
but the
lights are not.
1.
D
efective halogen bulb.
1. Change the halogen bulb.
2. The light bulb is loose.
2. Tighten the light bulb.
3. The wires on the switch are
loose.
3. Make sure the wires on switch
are connected properly.
The hood is not
venting out properly.
1. The hood might be hanging to
high from the cook top.
1. Adjust the distance between the
cook top and the bottom of the
hood within 26” and 36” range.
2. The wind from the opened
windows or opened doors in the
surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors
to eliminate the outside wind flow.
3. Blockage in the duct opening or
duct work.
3. Remove all the blocking from the
duct work or duct opening.
4. The direction of duct opening is
against the wind.
4. Adjust the duct opening
direction.
5. Using the wrong size of ducting.
5. Change the ducting to correct
size.
Metal filter is
vibrating.
1. Metal filter is loose.
1. Change the metal filter.
2. Spring clip is broken.
2. Change the spring clip.
異常狀況
原因
處理方式
安裝後電機不運轉
1.
無電源輸入
1.
檢查斷路器,並確認電源已接
上
2.
電源線和閉端沒有正確的安裝
2.
確認電源線和油機被正確的連
接
3.
旋鈕開關的電線鬆脫
3.
確認開關電線線被正確的連接
4.
開關有問題
4.
更換開關
燈亮但電機不運轉
1.
馬達有問題,也許卡住了
1.
更換馬達
2.
若運轉時馬達過熱將會啟動過
熱保護系統並關閉馬達
2.
待過熱保護系統冷卻後,馬達
將會再次正常運轉
3.
電容器損壞
3.
更換電容器
4.
馬達線路沒有連接
4.
確認馬達電線端子被正確地連
接
機體震動
1.
馬達不牢固
1.
檢查並鎖固馬達
2.
風葉輪損壞
2.
更換風葉輪
3.
機體懸掛不牢固
3.
檢查並校準機體
電機運轉但燈不亮
1.
燈泡損壞
1.
更換燈泡
2.
燈泡鬆脫
2.
重新旋緊燈泡
3.
開關的電線鬆脫
3.
檢查電線正常的連接
油機沒有正常排煙
1.
機體與爐面距離太大
1.
重新調整抽油煙機的高度,建
議油煙機與爐面的距離在
26”
到
36”
範圍之間
2.
機體周圍門窗太多,空氣對流
太大
2.
適度關閉門窗
3.
出風口或排氣管被阻塞
3.
清理阻塞物
4.
出風口逆風現象
(
倒灌風
)
4.
調整出風口的方向
5.
排風管尺寸錯誤
5.
更換正確的排風管尺寸
金屬濾網震動
1.
金屬濾網鬆脫
1.
更換金屬濾網
2.
彈片損壞
2.
更換彈片
X. Troubleshooting
Содержание PR836AS
Страница 2: ......