User Manual
PW-FE1-4Eth
E1-Ethernet Converter
www.pacificwave-wireless.com
Page 16 of 16
3
Indicator LOS
always lights when
the cable at the E1
port is connected.
The circuit
signals
are lost.
1. Check the coaxial cable or
UTP5 twisted pair for open
circuit and short circuit.
Check whether the plugs are
positioned well.
2. The factory default of the
device is 75Ω BNC interface.
If a 120Ω RJ45 interface is
used, S5.6~S5.8 should be
reconfigured. (See 4.2.3)
3. The internal circuit of the
equipment is damaged. Send
it to factory for repair.
4
Indicators are
normal, but
communication
can not be done.
Different
mode/
Setting
between
Local
device
and
Remote
Device
1.
The setting of framing or
un-framing are different.
Make sure both devices has
same code setting S1.1.
2.
Setting of the time slots are
different. Make sure both
devices set same time slots
via the dip switch
S1.2~S1.8, S2.1~S2.8,
S3.1~S3.8, S4.1~S4.8..