Bench Troubleshooting
Instruction and Service Manual
42
Pacific Scientific REDI-LINE Generators
TSBANOST
Inspect DC Brushes
See Brush
Inspection Procedure,
This Section
Inspect AC Brushes
See Brush
Inspection Procedure,
This Section
Inspect Diode
See Diode
Inspection Procedure,
This Section
Inspect Circuit Breaker
See Circuit Breaker
Inspection Procedure,
This Section
Inspect Solenoid(s)
See Solenoid
Inspection Procedure,
This Section
Okay
Yes
No
Okay
Yes
No
Okay
Yes
No
Okay
Yes
No
Okay
Yes
No
R eplace Armature
See Armature
Replacement,
Section 9,
Repair Procedures
Replace Diode
See Diode
Replacement,
Section 9,
Repair Procedures
Replace Circuit Breaker
See Circuit Breaker
Replacement,
Section 9,
Repair Procedures
Replace AC Brushes
See AC Brush
Replacement,
Section 9,
Repair Procedures
R eplace DC Brushes
See DC Brush
Replacement,
Section 9,
Repair Procedures
R eplace Solenoid(s)
See Solenoid
Replacement,
Section 9,
Repair Procedures
Return to
Service
FIELD COMPLAINTS
Generator does
not start when
connected to battery
Generator does
not start
automatically
Or
Newer
Version*
Older
Version*
Replace PC Board.
See PC Board
Replacement,
Section 9.
Repair Procedures
Okay
Yes
No
Model Serial Number
Break
* Older versions have
serial numbers at or
below those shown below.
DA12A
80294
DA12L
81221
DA24A
79632
DA24L
79203
DA36A
79632
DA36L
Figure 8-3. Generator Does Not Start When Connected to the Battery
or Does Not Start Automatically