Recommended Wiring Installation
DA12L-1600A and DA 3252
Infrequent Use with Varying Loads
If the load requirement is not heavy (intermittent
hand tool use or light loads for a long period of
time) install one or more auxiliary deep cycle
batteries. The auxiliary battery should be isolated
from the vehicle battery using a battery isolator. The
battery isolator is a one way path so both batteries
are charged by the vehicle but one battery cannot
discharge the other. This will ensure the vehicle
battery is always charged and you will be able to
start your vehicle.
To Vehicle
12 Volt
Battery
Jumper
Cables
+
–
+
–
REDI-LINE Generator
200 Amp
Fuse
To The
Alternator
To
Ground
–
–
+
+
12 Volt
Battery
Isolator
Isolator*
Fuse
Frequent Use with Varying Loads
If the load requirements are heavy (constant use of
hand tools or large loads) install two or more
auxiliary deep cycle batteries. The auxiliary batteries
should be isolated from the vehicle battery using a
battery isolator. The battery isolator is a one way
path so both batteries are charged by the vehicle but
one battery cannot discharge the other. This will
ensure the vehicle battery is always charged and you
will be able to start your vehicle.
To Vehicle
12 Volt
Battery
Jumper
+
–
+
–
REDI-LINE Generator
100 Amp
Fuse
100 Amp
Fuse
To The
Alternator
To
Ground
–
–
+
+
12 Volt
Battery
Isolator
12 Volt
Battery
+
–
To
Ground
Cables
Isolator*
Fuse
Isolator*
Fuse
6
*Use fuse size recommended
by isolator manufacturer