ADF SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 204 of 349
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:RANGe?
Description
Returns maximum DC voltage at which saturation of the output
inverter will occur. Saturation limits are determined in the maximum
peak voltage capability of the AC+DC components at the output of
the power source. For the AFX Series®, these limits are -425 and
+425V. The VOLT:DC1:SAT? returns the max. DC level that may be
programmed based on the programmed AC wave shape and RMS
level.
Maximum allowable values are:
Maximum positive peak voltage:
V_DC = V_peak_max - V_AC_peak_max
Minimum negative peak voltage:
V_DC = V_peak_min + V_AC_peak_min
Examples
V_AC = 300Vrms sine wave
V_DC = 425 - 1.41 *
300
(
V_DC_sat = 0
)
V_AC = 120Vrms sine wave
V_DC = 425 - 1.41 *
120
(
V_DC_sat = 255
)
V_AC = 0Vrms
V_DC = 425 –
0
(
V_DC_sat = 425
)
Returned Data Format
<nr2>
Query Example
VOLT:DC1:LIM:SAT:RANG?
-225, + 225
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MAXimum?
Description
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MAX?
254.946
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MINimum?
Description
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MIN?
-254.946