25
IMPORTANT:
After your outdoor kitchen is converted to natural gas, the working pressure for natural gas
is 7-inche water column (WC). Gas pressure is affected by gas line size and the length of
gas line run from house. Follow the recommendations in the chart below.
From House to Oven
Distance
Tubing Size
Up to 25 ft.
3/8 in. DIA
26
– 50 ft.
1/2 in. DIA
51
– 100 ft.
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
Over 101 ft.
3/4 in. DIA
IMPORTANT: Please be aware that the BTU rating of the rotisserie burner will
change after the oven is converted to natural gas. See below chart for reference:
Burner
LP Gas
Natural Gas
Main Burner
16,000 BTU / Hr
16,000 BTU / Hr
CAUTION:
If low flames or burner problems are observed after converting from LPG to NG, the natural
gas
lines may not be large enough. Refer to the “From House to Oven” chart
above
for
natural gas supply line specifications. Please contact a plumber to assure proper pressure
at 7-inch water column.
DO NOT RETURN YOUR OVEN TO THE STORE.