17
17
Fault error
System error, check motor connections.
18
18
Limit VREF error
Current too high on one of the two motors.
19
19
Limit VREF time error
Current too high on one of the two motors.
Display
STANDARD ERROR CODE
MEANING
DESCRIPTION/ACTION
97
System error
Restart the machine. A system error has
occurred, contact assistance if it persists.
99
System charging
System detected in charging mode. To reset,
unplug the charging cable and restart the
machine.
3.7 DANGERS
To reduce the risk associated with potential dangers, please adhere to the following:
Dangers and pinch points exist when performing the following maintenance:
•
When replacing the main and lateral brushes
•
When cleaning the vacuum filter
•
When adjusting the brush pressure
All maintenance operations must be performed with the machine turned off.
Also, there are appropriate signals on the machine alerting the operator.
Tipping Danger
Tipping danger may happen:
•
During the normal use when the machine passes the gradient limits specified in this manual
or when the machine is used on irregular surfaces. (section 3.2)
•
Don’t use the machine on surfaces exceeding 5% of slope or irregular surfaces
that may cause instability.
Pacific Floorcare shall not be held liable for accidents to persons or things when using the
machine on surfaces that can compromise stability. The operator has to follow
recommendations about environmental conditions in the areas where the work is to be
performed.