To Turn Off Gas Appliance.
1. Place ON/OFF switch (if equipped) in
O
(OFF) position.
2. If gas control is accessible, turn main valve knob to the
OFF
full clockwise position.
Automatic Turn Down
3 Hour No Communication Function
•
The valve will turn to pilot flame if there is no communication between handset and receiver for a 3 hour
period. The fire will continue to function normally when communication is restored.
Receiver Overheating
(only if module is connected)
•
Valve turns to pilot flame if the temperature in the receiver is higher than 140°F (60°C). The main burner
turns back on (manually or in Thermostatic Mode) only when the temperature is below 140°F (60°C).
1 Hour Turn Down for Special Receiver
(e.g. fireplaces in bedrooms)
•
The valve will turn to pilot flame if there is no motor movement over a 1 hour period.
Automatic Shut Off
Countdown Timer
•
At end of countdown time period, the fire turns off. The Countdown Timer only works in manual,
Thermostatic, and Eco Modes. Maximum countdown is 9 hours and 50 minutes.
Low Battery Receiver
•
With low battery power in the receiver, the system shuts off the fire completely. This will not happen if the
power supply is interrupted.
On-Demand Pilot
•
The green feature eliminates gas energy consumption during extended appliance inactivity. When the
appliance is inactive for an extended period of time, the system automatically extinguishes the pilot. This
feature helps the consumer realize cost benefits by automatically eliminating energy consumption during
non-heating months and limited use.
•
The programmed length of inactivity to activate the system is specified by the appliance manufacturer and
cannot be altered in the field.
i20 TOFINO
24
150317-32
5055.980-A