background image

Figure 6: Temperature in  

 

celcius.

Figure 7: Temperature in  

 

fahrenheit.

Figure 8:  Key lock icon.

Figure 5:  On Off switch for SIT units.

i20 TOFINO 

Temperature indication Display

 

With the system in the “OFF” position, press the Thermostat Key and the 
Mode Key at the same time. Look at the LCD screen on the transmitter to 
verify that a C or F is visible to the right of the Room Temperature display 
(Figure 6 and Figure 7).   

Turn on the Fireplace 

With the system OFF, press the ON/OFF Key on the remote transmitter. The  

remote transmitter display will show some other active Icons on the screen.  

At the  same time the Receiver will activate the Heater. A single “beep” from 

the Receiver  (module) will confirm reception of the command.  

Turn off the Fireplace  

With the system ON, press the ON/OFF Key on the Remote transmitter. 

The  Remote transmitter LCD display will only show the room temperature 

(Figure 6 and Figure 7). At the same time the Receiver (module) will turn off 

the Heater. A single “beep”  from the Receiver confirms reception of the 
command.  

Manual Bypass of the Remote System

 

If the batteries of the receiver or remote transmitter are low or depleted, the 
Heater can be turned off manually using ON/OFF switch located on the 

left hand side of the backing plate (Figure 5). This will bypass the remote 
transmitter.  

Key Lock

 

This function will lock the keys to avoid unsupervised operation. To activate 

this  function, press the MODE and UP keys at the same time. The lock icon 
will appear (Figure 8). To de-activate this function, press the MODE and UP 
keys at the same  time.   

Room Thermostat (Transmitter Operation)   

The Remote Control can operate as a room thermostat. The thermostat  

can be set to a desired temperature to control the comfort level in a room.   

To activate this function, press the Thermostat key (Figure 1). The LCD  

display on the transmitter will change to show that the room thermostat  
is “ON” and the set temperature is now displayed (Figure 9). To adjust 
the  set point, press the up or down arrow keys until the desired set point  
temperature is displayed on the LCD screen of the transmitter.   

Room Temperature

Set Temperature

Figure 9:  Room temperature control.

9

5055.980-A

150317

-32

Содержание TOFINO i20

Страница 1: ...other gases unless a certified kit is used FOR YOUR SAFETY Donotstoreorusegasolineorother flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do no...

Страница 2: ...t Pilot CPI IPI selection 12 Remote Control Operation Maxitrol 13 Operating Instructions 13 Setting the Electronic Code 14 Setting Fahrenheit or Celsius 15 Setting the Time 15 Child Proof 15 Manual mo...

Страница 3: ...cess of 1 2 psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system a...

Страница 4: ...door removed for servicing the unit must be replaced prior to operating Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least...

Страница 5: ...slight odour for a couple of hours This is due to the curing of paints sealants and lubricants used in the manufacturing process This condition is temporary Open doors and windows to ventilate area Od...

Страница 6: ...yout and informative LCD display Figure 1 The transmitter is powered by 3 AAA type batteries A Mode key is provided to Index between the features and a Thermostat key is used to turn on off or index t...

Страница 7: ...power to the IFC allowing the batteries to be used only when line power is interrupted or lost and if the Heater does not use a combustion fan Operating Procedure Initializing the system for the firs...

Страница 8: ...Figure 3 SIT electronic controller IFC mounted onto caddy PRG Figure 4 Program button ON REMOTE OFF Figure 5 On Off switch for SIT units i20 TOFINO 8 150317 32 5055 980 A...

Страница 9: ...reception of the command Manual Bypass of the Remote System If the batteries of the receiver or remote transmitter are low or depleted the Heater can be turned off manually using ON OFF switch located...

Страница 10: ...me on in the high position Figure 10 A single beep will confirm reception of the command Flame Off Flame level 5 Flame level Max Flame level 1 Figure 10 Flame level control Split Flow Function The sec...

Страница 11: ...point press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter Figure 14 Comfort Fan Speed Control The SIT version heater is equ...

Страница 12: ...t set point etc When the IFC batteries are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC boa...

Страница 13: ...mage the electronics Batteries Handset Low battery indicator on handsets Batteries Receiver Low battery indication frequent beeps for 3 seconds when motor turns Program Mode Temperature Time Countdown...

Страница 14: ...is complete Activation is complete when the function icon is displayed The following Functions can be Deactivated Activated CHILD PROOF PROGRAM MODE THERMOSTATIC MODE also deactivates PROGRAM MODE ECO...

Страница 15: ...d buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait ON To activate press and buttons simultaneously is displayed and the ha...

Страница 16: ...on Main gas flows once pilot ignition is confirmed Handset automatically goes into Manual Mode after main burner ignition NOTICE Change from two button to one button ignition operation by pressing and...

Страница 17: ...et appliance to pilot flame press and hold button To go to low fire double click button is displayed NOTE Flame goes to high fire first before going to low fire To go to high fire double click button...

Страница 18: ...flash 4 To select minutes press or button 5 To confirm press or wait OFF Press button and countdown time disappears Thermostatic Mode The room temperature is measured and compared to the set temperat...

Страница 19: ...FF displayed OFF 1 Press or or button to enter Manual Mode 2 Press button to enter Thermostatic Mode NOTE The set temperature for Thermostatic Mode is the temperature for the on time in Program Mode C...

Страница 20: ...hes 8 To select hour press or button 9 To confirm press button 1 ON displayed displayed shortly and minutes flash 10 To select minutes press or button 11 To confirm press button 12 1 OFF displayed is...

Страница 21: ...the instructions To Turn Off Gas Appliance on page 24 WARNING NOTE Either continue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRA...

Страница 22: ...Increase flame height C Decrease flame height B ON OFF Figure 41 Touch pad Backing plate switch ON OFF Flame UP Down Figure 42 On Off switch location for Maxitrol units i20 TOFINO 22 150317 32 5055 98...

Страница 23: ...follow the instructions To Turn Off Gas Appliance on page 24 WARNING Standby mode pilot flame Press and hold C button to set appliance at pilot flame To turn off appliance Press B button Flame height...

Страница 24: ...t flame if there is no motor movement over a 1 hour period Automatic Shut Off Countdown Timer At end of countdown time period the fire turns off The Countdown Timer only works in manual Thermostatic a...

Страница 25: ...ver s reset button Figure 43 until you hear two 2 beeps After the second longer beep release the reset button Within the subsequent 20 seconds press the DOWN ARROW button on the handset until you hear...

Страница 26: ...ust be allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off switch to the fireplace Off 5 Allow sufficient length of time minimum 5 minutes for any gas in...

Страница 27: ...baffle for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean logs and burner with a brush or vacuum cleaner payin...

Страница 28: ...surround by lifting it from the backing plate and set aside 2 Remove the backing plate by moving it away from the fireplace Be sure to disconnect the wire on the left hand side of the backing plate Th...

Страница 29: ...the door and set aside Installation 1 Place the door over the opening of the fireplace 2 There are two hooks on the top of the handles and two hooks on the bottom of the handle and so the door must b...

Страница 30: ...i20 TOFINO 30 150317 32 5055 980 A...

Страница 31: ...i20 TOFINO 31 5055 980 A 150317 32...

Страница 32: ...LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pa...

Отзывы: