background image

INSTALLATION AND OPERATING

INSTRUCTIONS

FOR VENT-FREE

OR VENTED INSTALLATIONS

GOLDEN BLOUNT “TEXAS FLAME II” GAS LOGS

NATURAL GAS OR L.P.

18“ - 24“ & 30“ SIZE SETS

The Golden Blount vent-free gas
log sets comply with the National
Safety Standards and are tested
and design certified by CSA to
ANSI Z21.11.2-2000, unvented
heaters Z21.60a-2000 decorative
gas appliances for installation only
in a woodburning, masonry or UL
listed manufactured fireplace or in a
Golden Blount or any other CSA
approved vent-free fireplace. This
product may be burned with the
fireplace damper in either a closed
or open position.

Warning:

 If the information in this manual is

not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life

• Do not store or use gasoline or other

flammable vapors or liquids in the
vicinity of this or any other appliance.

• What to do if you smell gas:

- Do not try to light any appliance.

- Do not touch any electrical switch;

do not use any phone in your
building.

- Immediately call your gas supplier

from a neighbor’s phone.

- If you cannot reach your gas

supplier, call a fire department.

- Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

Warning:

 Logs must be arranged so that the

flames only touch bottom back log or front
ember log. Flames must not touch any other
log in set or any part of firebox.

This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilation air must be
provided.

MANUFACTURED BY:

4301 WESTGROVE DRIVE

ADDISON, TX. 75001

INC.

D

E S I G N

C

E

R T I F I E

D ®

Содержание 18" - 24" & 30"

Страница 1: ... personal injury or loss of life Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone If you cannot reach your gas supplier call a fire department...

Страница 2: ...tly closed at time of appliance installation Disconnect the gas appliance and its individual shut off valve from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa Isolate the appliance from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at t...

Страница 3: ...ay to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Note Installation and repair should be done by a qualified person well trained in the installation of such appliances You may need a building permit from your local Building Commissioner before installing this appliance Any safety screen or guard removed for servicin...

Страница 4: ...e paint by qualified chimney cleaner If a 1 2 gas supply line is not already installed in the fireplace a call to your plumber is recommended Check to make sure the gas supply is the same type natural or L P as listed on the rating plate attached to the burner Note the approved gas pressure chart Manifold pressure check should be made with the appliance burning in the high setting A 1 8 NPT test p...

Страница 5: ... use only parts specifically approved with this heater may result in property damage or per sonal injury NOTE Logs must be arranged so that the flames only touch bottom back log or front ember log Flames must not touch any other log in set NOTE Flames must not touch any part of firebox housing Damper handle firebox roof etc After positioning the logs on the burner grate pour the black lava rock in...

Страница 6: ... use only parts specifically approved with this heater may result in property damage or per sonal injury NOTE Logs must be arranged so that the flames only touch bottom back log or front ember log Flames must not touch any other log in set NOTE Flames must not touch any part of firebox housing Damper handle firebox roof etc After positioning the logs on the burner grate pour the black lava rock in...

Страница 7: ...ghtly and turn clockwise to the OFF position NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed slightly Do not force 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP follow B in the safety information listed above If you don t smell gas go to the next step 4 Find Pilot follow metal tube from gas control The pilot is locat...

Страница 8: ...elease ignitor button This will light pilot The pilot is attached to the main burner If needed keep pressing ignitor button until pilot lights NOTE If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match see manual lighting procedure 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds re...

Страница 9: ... Now follow step 9 lighting instructions 12222222222223 4 5 4 5 4 5 4 5 4 5 4 5 4 5 67777777777778 LIMITED WARRANTY Golden Blount Gas Logs are warranted against defective materials and or workmanship for as long as you own them Burner Assembly is guaranteed for five years from date of purchase ODS Pilot Assembly and valve are covered for one year This warranty does not cover parts subjected to mis...

Страница 10: ...IFY MODEL AND GAS TYPE 14 1 PILOT ASSEMBLY O D S SPEC MODEL AND GAS TYPE 15 1 PIEZO IGNITOR 16 1 CONTROL VALVE SPECIFY MODEL AND GAS TYPE 17 1 IGNITOR WIRE 18 1 GAS REGULATOR SPECIFY MODEL AND GAS TYPE 19 1 BURNER ORIFICE SPECIFY MODEL AND GAS TYPE 20 1 CONNECTOR TUBE 21 1 DAMPER CLAMP 22 1 1 2 MPT X 3 8 FLARE 90 DEGREE ELBOW 23 1 BLACK LAVA ROCK 24 1 GLOWING EMBER MATERIAL 25 1 ROCKER SWITCH NOT ...

Страница 11: ...tight in valve C Weak pilot flame 1 Pilot flame must engulf thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple D Defective valve 1 Replace valve 3 No gas to main burner A Plugged main burner orifice 1 Carefully remove and clean orifice with pilot flame burning and valve turned to On position B Defective valve 2 Replace valve 4 Soot accumulating on logs A Flame tou...

Отзывы: