SUMINSERTA 160309-20
9
Combustion Air
Consult local building codes regarding combustion air sup-
ply. Intake or combustion air can be supplied to the Insert
in one of two ways:
1) Outside air supply: Remove cover from ash clean out
in existing fireplace. Place a rodent screen in place of
the cover. Install the Insert as described in the "Instal-
lation" section, making sure not to cover the opening of
the air inlet. When installation is complete, seal surround
to fireplace and anywhere else air may enter. This will
ensure combustion air is drawn from outside the house
and into the 9" x 2" intake at the lower rear of the appli-
ance.
2) Room air supply: Remove the 4" knock-out plug from
the casing side prior to installation (Fig. #14). Install the
Insert as described in the "Installation" section. The
Insert will now draw its air from the room through the
front grill.
Fig. # 14
Knock-out Plug
Blower
The Insert comes equipped with a variable speed circulating
air blower. The blower system is thermostatically controlled
for automatic operation, as well manually with a convenient
bypass switch.
Blower Operation
Automatic:
To operate the blower automatically, push the
rocker switch to the “0” or OFF position and set the fan speed
control to a desired setting.
This will allow the blower to turn on automatically once the
Insert has come up to operating temperature. It will also shut
the blower off after the fire has gone out and the appliance
cooled to below a useful heat output range. On and Off times
will vary with installation and location of appliance.
Manual:
To manually operate the blower, push the rocker
switch to the “1” or ON position and set the fan speed control
to a desired setting. This will bypass the temperature switch
and allow full control of the blower.
Suggested settings:
- Combustion air control setting of "L" (low), operate
blower speed control on “Low”.
- Combustion air control greater than "L" (low), operate
blower speed control at desired setting.
Electrical Supply
Circulating air blower electrical rating; 115V, 60 Hz, 80 Watts.
For your protection against shock hazard, use only a properly
grounded outlet that will accept a three-pronged plug. Do
not cut or remove the grounding prong.
Consult local codes or in the absence of local codes, with
the current CSA C22.1 Canadian Electrical Code and in
the USA with the National Electrical Code, ANSI/NFPA 70
(latest edition).
Fig. # 15
L2 (black)
G (green)
L1 (white)
Speed
Control
Blower
Thermo
Switch
By-pass
Rocker Switch