10 SUPER-SD1 

280514-24

16" [406mm]

8" [203mm]

8" [203mm]

Canada Only

Floor Protector

The stove may be installed on a combustible fl oor provided 
noncombustible ember protection is used.
This protection must extend as follows:

In Canada:  18" (457 mm) on the fi ring side and 8" (203 mm) 
to the other sides. See Figure #3, below.

Combustion Air

Intake or combustion air can be supplied to the stove in one 
of two ways.  Consult your local building code or CAN/CSA-
B365, Installation Code for Solid-Fuel-Burning Appliances 
and Equipment before proceeding.

1. 

Outside air supply 

- (Necessary for mobile home instal-

lation, optional for residential installation.) Outside air 
may be drawn from either underneath the stove or from 
behind.

 

To draw outside air through the fl oor, leave the 4"(100mm) 
knockout or cover plate in place in the rear of the pedestal 
or leg kit ash box enclosure.

 Pedestal 

Model:

  Cut or drill a 4" (100mm) diameter hole 

in the fl oor anywhere inside the perimeter of the pedestal.  
Cover the hole with a 4" x 4" (100 mm x 100 mm) rodent 
screen and staple/nail in place.

 Leg 

Model:

  Cut or drill a 4"(100mm) diameter hole directly 

below the bottom hole of the ash box enclosure.  Connect 
enclosure to the fl oor with a short 4"(100mm) diameter 
pipe. If you wish to connect the outside air to the rear hole 
on the ash box, then remove the 4"(100mm) knockout or 
cover plate at the rear of the ash box.

 

This hole must get its air from a 

ventilated

 crawl space 

or be extended with duct to the outdoors (see Figure #3, 
Page 7).  The use of outside combustion air for residential 
installation requires the unit to be secured to the structure 
to prevent dislodging of the air duct.  

 

To draw outside air from behind the stove, an outside air 
adaptor may be required (see Optional Blower section). 
Cut or drill a 4"(100mm) hole through a wall behind the 
unit. Use an appropriate household 4"(100mm) inlet. You 
must remove the rear cover plate from the pedestal or 
move the cover plate at the rear of the leg kit ash box 
enclosure to cover the bottom hole.

Note:

 

This unit is not designed to be operated with the fi ring 

door open. In addition to the obvious hazard of sparks 
landing on combustibles, an open fi re door will cause 
the heater to draw air from the living space and possibly 
cause suffocation.

2. 

Room air supply 

- Remove the cover plate from the rear 

of the pedestal or leg kit ash box enclosure.  The stove 
will now draw its air from the room through this opening 
and into the fi rebox intake.

Note:

  The living space around the heater must be well 

ventilated with good air circulation.  Anything that may 
cause a negative pressure can cause gases or fumes 
to be pulled into the living area.  During extremely cold 
weather, and especially when burning at very slow rates, 
the upper parts of the exposed chimney may ice up, 
partially blocking the fl ue gases.  If blockage occurs, fl ue 
gases may enter living space.

U.S.A. Only

Non-combustible 

fl oor protector

FIG. #3

FIG. #4

In USA:  16" (406 mm) to the front and 8" (203 mm) to the 
sides of the fuel loading door opening.  See Figure #4, below.  
This protection is also required under the chimney connector 
and 2" (51 mm) beyond each side.

8"  [203mm]

18"   [457mm]

8"  [203mm]

8"   [203mm]

Minimum Width - 40'(1.02m)

Minimum Overall Depth - 50 1/2"(1.28m)

Non-combustible 

fl oor protector

Minimum Width - 34"(864mm)

Minimum Overall Depth - 40 1/2"(1.03m)

Содержание SPECTRUM

Страница 1: ...tioninstructions Contact local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmental...

Страница 2: ...ce 3 Maintenance Checks 4 Creosote 5 Formation and Need for Removal 5 Chimney Fires 5 In Case of a Chimney Fire 5 Avoiding a Chimney Fire 5 Assembly 6 Crate Removal 6 Optional Ash Cleanout System Inst...

Страница 3: ...tained in good condition Periodically inspect seals and replace if neces sary Follow instructions included in the DR31 WDGKIT kit obtainable from your nearest Pacific Energy dealer 5 DOOR GLASS Do not...

Страница 4: ...himney System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn...

Страница 5: ...nd must be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creo...

Страница 6: ...at secure stove body to bottom pallet 4 Place stove body carefully on its back 5 Using two 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom O...

Страница 7: ...leaks 6 Install connector as per manufacturer s instructions 7 Attach stove to flooring using two 1 4 x 2 or longer lag screws Mobile Home Installation Warning Undernocircumstancesisthisheatertobeins...

Страница 8: ...ney Support 56 1422 mm Minimum Minimum 7 2 1m Ceiling Height Attachment to floor for mobile homes Non combustible floor protector 48 1219 mm 3 914 mm Minimum Hooded vent or 90 elbow turned down The ch...

Страница 9: ...ffect stove performance Chimney flue exit is to be 3 feet 1 m above roof and two feet 0 6 m above highest projection within 10 feet 3 m The installation must meet all local codes Do not connect this u...

Страница 10: ...equires the unit to be secured to the structure to prevent dislodging of the air duct To draw outside air from behind the stove an outside air adaptor may be required see Optional Blower section Cut o...

Страница 11: ...for the first 2 3 times it is very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the curing process may cause discomfort to some individuals Lighting...

Страница 12: ...Overnight Burns 1 Open door and rake hot embers towards the front of the heater Add a couple of dry split logs on top of embers close door 2 Adjust air control to high and in just a few minutes logs...

Страница 13: ...perate as follows Air control set to L low operate blower speed control on Low Air control set between L and H low and high oper ate blower speed control at desired setting Automatic To operate the bl...

Страница 14: ...latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t B...

Страница 15: ...Door Handle Assembly WODC 4147C 11 Boost Manifold 4105 12 Firebrick Set BRIC SSERA 13a Brick Rail Left Right SSER RAILSET 14 Replacement Baffle Kit SSER DBAKIT 15 Baffle Pin SSER 125001 16 Baffle Gas...

Страница 16: ...kel CAST 31NI Door Casting Radiant Nickel CAST 31RSNI 12 Door Handle Assembly WODC 4147C 13 Boost Manifold 4105 14 Firebrick Set BRIC SSERA 15a Brick Rail Left Right SSER RAILSET 16 Replacement Baffle...

Страница 17: ...ng the basic functions of this design Traditional wood stoves had a basic combustion system which allowed a considerable amount of heat energy to escape up the chimney as unburned gases and particulat...

Страница 18: ...ts back 5 Using a 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Pedestal Kit 1 With the unit on its back and the removable cover facing up...

Страница 19: ...either A B C as shown below if you are installing the optional ash cleanout system or 1 full brick in place of A B if you are not installing the ash cleanout system Next install the side firebricks 4...

Страница 20: ...20 SUPER SD1 280514 24...

Страница 21: ...280514 24 SUPER SD1 21...

Страница 22: ...22 SUPER SD1 280514 24...

Страница 23: ...07 INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D INSTALLATION ET D OP RATION FOURNI AVEC L APPAREIL CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX...

Страница 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...

Отзывы: