Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific
Energy, ALT 1.2 Freestanding wood heater.
This heater meets the 2015 U.S. Environmental Protection Agency's
crib wood emission limits for wood heaters sold after May 15, 2015.
Model ALT 1.2: 2.6 g/hr.
Under specific test conditions this heater has been shown to deliver
heat at rates ranging from 13,500 to 27,000 Btu/hr.
SAFETY NOTICE:
If this stove is not properly installed, a house fire
may result. For your safety, follow the installation instructions. Con-
tact local building or fire officials about restrictions and installation
inspection requirements in you area.
Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage,
bodily injury, or even death.
EPA Certified Emissions
2.6 grams per hour
LHV Tested Efficiency
1
80.4%
HHV Tested Efficiency
2
74.4%
EPA BTU Output
3
13,500 - 27,00 btu/hr
Peak BTU/Hr Output
4
32,200
Maximum Wood Length
17 inches
Ideal Wood Length
16 inches
Fuel
Seasoned Cordwood
1 Weighted Average Lower Heating Value (LHV) efficiency as tested
using
CSA B415 Performance testing of solid-fuel-burning heating
appliances.
LHV assumes the moisture is already in a vapour state so
there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency as tested
using
CSA B415 Performance testing of solid-fuel-burning heating
appliances.
HHV includes the energy required to vaporize the water in
the fuel
3 The range of BTU outputs is based on efficiency using
CSA B415
Performance testing of solid-fuel-burning heating appliances
and
burn rates from the low and high EPA tests using Douglas Fir dimen-
sional lumber.
4 The Peak BTU/hr is based on efficiency using
CSA B415 Per-
formance testing of solid-fuel-burning heating appliances,
the
Maximum one hour High burn rate from the High Burn EPA test and the
BTU content of cordwood (8600 btu/lb).
Experience will give you the right settings for proper combustion
and efficient burning. Remember the correct air inlet setting is
affected by variables such as type of wood, outside temperature,
chimney size and weather conditions. With practice, you will
become proficient in operating your heater and will obtain the
performance for which it was designed.
Efficiency and BTU Output
210618-28_ALT 1.2
210618-28_ALT 1.2
3
5055.7298-A